![Neutec MIDI00SP Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/neutec/midi00sp/midi00sp_operators-handbook-manual_1676425021.webp)
Operator’s Handbook
Ca
pi
tol
o:
Di
ag
no
st
ics
21
Diagnostics
Errors and Warnings
In the event one of these messages appears on the display, take the action described in the "Solution" section of the message.
Errore 1: H2O flux failure
Problem:
The flux sensor does not measure the presence of liquid in the cooling system.
Solution:
Check out the coolant level
Check out and clean up the water filter
Call for the service
Errore 2: Cap. Charge fail
Problem:
Internal capacitors are not fully charged or not charged at all
Solution:
•
Check the power line
•
Check if there are problems on the power supply electric network
•
Check the actual working voltage
•
Call for the service
Errore 3: Simmer failure
Problem:
The flash lamp is not ignited (Simmering)
Solution:
•
Check the shoots made
•
Call for the service
Errore 4: Shutter failure
Problem:
The cavity safety fails to close or is malfunctioning
Solution:
Call for the service
Errore 5: RS-232 fail
Problem:
The comunication beetwen the circuit board inside the machine is not working
Solution:
Call for the service
Warnings
All the below ”Warning” messages are displayed because of external conditions affecting the proper functioning of the equipment and can be
solved without switching it off
Warning 1: Remote interlock
Syntom:
Remote interlock open
Solution:
Close the remote interlock contact to start working again
Warning 2: H2O too hot
Syntom:
Cooling liquid temperature too high
Solution:
Wait until the machine re-starts automatically.
(Do not turn the system off!)
If the machine doesn’t start automatically call for the service
Warning 3: CCPS too hot
Syntom:
Electronics temperature too high
Solution:
Wait until the machine re-starts automatically.
(Do not turn the system off!)
If the machine doesn’t start automatically call for the service
Do not place the equipment in a hot environment. An increased ambient temperature reduces the efficiency of the cooling system.
Warning 4: Pendrive unplugged
Syntom:
No pen drive in, no data saving nor retrieving. Please check if the pen drive is plugged properly in.
Solution:
Check for correct insertion of the pen drive.
The machine will work without pen drive but user cannot save settings.