manualshive.com logo in svg
background image

Safety Information

Intended Use:

AvivaTens XP delivers stimulation based on the principles of transcutaneous electrical nerve stimulation (TENS) as described

in the following. Short electrical pulses are sent via self-adhesive electrodes to the surface of the skin.

Powered muscle stimulators should only be used under medical supervision for adjunctive therapy for the indications

listed below.

Transcutaneous Electrical Nerve Stimulation (TENS)

TENS is a pain therapy based on the application of electrical stimuli to the skin via stimulation of the nerve fibers. There are

two methods: The “pain gate” theory, which blocks the pain signals to the brain and/or through the increased release of

endorphins, which inhibits the emergence of pain.

Indications

• The symptomatic relief and management of chronic intractable pain. It is also an adjunctive treatment in the management

of post-surgical and post-traumatic pain. The device has no curative value and should only be used in conjunction with

medical supervision.

Contraindications

• Patients with electronic implants (e.g. cardiac pacemaker or defibrillator - as your neurotech product may interfere with the

proper functioning of the implanted stimulator) or if you suffer from any other heart problem.

Warnings

•  The long-term effects of chronic electrical stimulation are unknown.

•  Stimulation should not be applied over the carotid sinus nerves, particularly in patients with a known sensitivity to the

carotid sinus reflex.

•  Stimulation should not be applied over the neck or mouth. Severe spasm of the laryngeal and pharyngeal muscles may

occur and the contractions may be strong enough to close the airway or cause difficulty in breathing.

•  Stimulation should not be applied transthoracically in that the introduction of electrical current into the heart may cause

cardiac arrhythmias.

1

S

A

F

E

T

Y

 I

N

F

O

R

M

A

T

IO

N

Содержание AvivaTens XP

Страница 1: ......

Страница 2: ......

Страница 3: ...is to design products that help accelerate recovery and return patients to a more active lifestyle If you have further questions regarding AvivaTens XP please contact your prescribing physician or dis...

Страница 4: ...eliability and performance of the equipment when it is operated in accordance with the instructions herein and within the given specifications Therefore the user must bear full responsibility for any...

Страница 5: ...TROLS 5 DESCRIPTION OF APPARATUS DISPLAY 7 STEP BY STEP TREATMENT GUIDE 9 SYSTEM MAINTENANCE 13 TROUBLESHOOTING 15 TECHNICAL INFORMATION 16 UNIT SETTINGS AND ELECTRODE EQUIPMENT FOR YOUR THERAPY 19 UN...

Страница 6: ...lso an adjunctive treatment in the management of post surgical and post traumatic pain The device has no curative value and should only be used in conjunction with medical supervision Contraindication...

Страница 7: ...tween However placement on the nearest muscle is possible If in doubt seek medical advice Precautions should also be taken if muscle stimulation occurs during heavy menstruation or in the same month a...

Страница 8: ...nical Data for more details If any irritations skin reactions over sensitivity or other side effects occur please contact Bio Medical Research Ltd In such cases stop use immediately Irritations can us...

Страница 9: ...Your AvivaTens XP package includes 1 AvivaTens XP unit 2 Instruction Manual 3 A 9 volt battery 4 Connecting Leads 5 Electrodes 6 Device box WARRANTY Should your unit develop a fault within two years...

Страница 10: ...Controls Channels 1 and 2 Each intensity control governs one channel on the same side of the unit Pressing the upper button during treatment increases the intensity level by a factor of one for that...

Страница 11: ...rst mode is selected during Program 2 the unit delivers a signal with a frequency of 99Hz at a pulse width of 120 s for 3 seconds This then returns to the normal program frequency and pulse width for...

Страница 12: ...eplace or check the battery follow the instructions on page 13 Connecting Leads Two sockets are located at the base of the unit for the insertion of the leads Fig 2 The leads are connected to the elec...

Страница 13: ...n relaxation cycle on each channel 4 Displays the length of time left elapsed in the current session in hours minutes and seconds For a set treatment time program the timer will count down in minutes...

Страница 14: ...g the leads to the unit attach each lead to an electrode Fig 5 5 AvivaTens XPis supplied with a set of electrodes The electrodes should be handled as stated in the manual Please note the following poi...

Страница 15: ...3 seconds The total treatment time will reset to zero Display 3 The maximum total treatment time is 99 hours and 59 minutes It will reset back to 00 00 when the maximum treatment time is reached 10 S...

Страница 16: ...riefly press the on off button The unit issues a beep and the pause icon appears on the display in order to signal that the program has been paused Display 7 To deactivate the pause function press the...

Страница 17: ...scle spasm 16 AvivaTens XPhas a load sense function that monitors the connection between the lead and its electrode and between the electrode and the skin When poor skin contact is detected Display 9...

Страница 18: ...t is located on the rear of the AvivaTens XP unit In order to open the battery compartment turn the AvivaTens XP over Press your thumb against the symbol shown on the battery compartment to unlock it...

Страница 19: ...er electrodes and leads may degrade performance levels Do not dispose of used electrodes and batteries in household rubbish or in an open flame dispose of them in accordance with regulations in your c...

Страница 20: ...ly inserted Broken lead The battery is low Faulty lead Check your skin for lotions pigment marks dry spots or other factors that could increase resistance Faulty lead assembly Electrode faulty Poor sk...

Страница 21: ...cations Operation Temperature 32 to 131 F Humidity 20 to 65 RH Storage Temperature 32 to 131 F Humidity 10 to 90 RH XP units are products of Bio Medical Research Ltd Parkmore Business Park West Galway...

Страница 22: ...entation This symbol means Type BF equipment SN stands for serial number On the rear of each XP model is the unit s individual serial number The letter preceding the serial number indicates the year o...

Страница 23: ...ore information about collection points in your area Waste Electrical and Electronic Equipment can have potentially harmful effects on the environment Incorrect disposal can cause harmful toxins to bu...

Страница 24: ...sible with programs 1 4 5 Note If the unit s display shows a different program from the one prescribed by the clinician when you switch it on please do the following 1 Switch the device off and on the...

Страница 25: ...ECTRODE PLACEMENT GUIDE right left left right dorsal ventral Note for the clinician Please enter the desired electrode place ment in the adjacent drawing Connect the adjacent channels with a straight...

Страница 26: ...21 ELECTRODE PLACEMENT GUIDE ELECTRODE PLACEMENT GUIDE The following images show several possible electrode placements However you should only place electrodes as directed by your physician...

Страница 27: ...22 ELECTRODE PLACEMENT GUIDE...

Страница 28: ...ulus of 4Hz When the Trigger button is pressed a high frequency 99Hz stimulus is delivered To disable High Frequency Trigger mode press the Trigger button a second time Program 2 3 Burst Mode Burst mo...

Страница 29: ...a stimulus of 4 to 99Hz Trigger mode is available on Program 4 and 5 When the Trigger button is pressed Trigger mode is enabled When the button is pressed a second time the unit enters a contraction...

Страница 30: ...25 NOTES...

Страница 31: ...26 NOTES...

Страница 32: ...Part No XXXX XXXX Rev 1A Issued 12 09...

Отзывы: