3
4. Operating and storage conditions
4.1. Technical data:
Housing material *
AISI 304
Internal components material * AISI 304
Spring material
Chrome silicon alloy (coated)
Piston material
Engineering polymer
Seal material *
Engineering elastomers
Operating temperature *
-10°c to +60°c
SR Operating pressure
5 - 8 bar
DA Operating pressure
4 - 8 bar
Rotation
90°±5°
Torques
See catalogue
Pneumatic interface *
Metric
Control devices interface
VDI/VDE 3845 (optional)
Control media*
Filtered air according to DIN
ISO 8573-1/class 4
Air filtration rate
30 micron (or less)
Usage
Indoor / Outdoor / Corrosive
environment
* For other options contact EGMO
4.2. Storage:
4.2.1. Store the actuators inside their original package.
4.2.2. Store the actuators indoors, in dry and clean place.
4.2.3. It is recommended to cycle the actuators during long
period storage.
4.3. Unpacking:
4.3.1. Before unpacking the actuator, insure that product
received comply with packing list.
4.3.2. Inspect the actuator to any damages (contact your
shipper if damages found).
4.3.3. Remove protection plugs close as possible to installation.
Installation