NEULOG ROTARY MOTION LOGGER SENSOR GUIDE
4.
After the experiment has concluded (the “Start/Stop” button is pressed again or
the data collection period ends) connect the sensor to your chosen device (you
can find full instructions in each device’s quick start procedure section).
5.
Open the NeuLog application.
6.
Click the “Off-line experiment” icon.
7.
Click the “Load data from sensors” icon.
8.
Select which experimental data to upload (5 experimental runs can be stored at
one time on the NUL-226 rotary motion sensor).
Restoring sensor’s factory default settings:
Procedure:
1.
Connect the USB-200 to a PC, Mac, tablet, or smart device.
2.
Connect the rotary motion sensor to a USB-200 module (they directly plug
together).
3.
Open the NeuLog application.
4.
Click the “Tools” icon.
5.
Click the “Restore sensor’s factory defaults” on the menu.
Included with the sensor:
NeuLog NUL-226 Rotary Motion Sensor Guide (this document).
Rotary motion revolving head piece attached directly to the sensor's body by a
durable rubber-coated wire.
Sensor's specifications
Range and
operation modes
ADC
resolution
Resolution
Max
sample
rate
(S/sec)
°
0 to 360
16 bit
0.09
100
Rad/s
±345
0.6
Rad/s
2
±32,222
14
Rev/s
±55
0.03
Experiment Duration
: 1 second to 31 days.
Sensor's features:
Fully digital data
Rugged plastic ergonomic case
Rotary motion rotating head piece attached directly to the sensor's body by a
durable rubber-coated wire
Push button switch for Start/Stop experiments in off line mode
LED indicator of experiment status (blinks while collecting data)
Pre-calibrated sensing equipment
Note:
NeuLog products are intended for educational use.
Videos and experiment examples:
Videos, literature and other probes can be found at
In order to access the rotary motion sensor's page, choose "Products" on the
main menu and then "Rotary motion logger sensor".
In order to find the science experiments, choose "Experiments" on the main
menu of the NeuLog website, then choose "Physics", "Chemistry", "Biology" or
"Environmental Science".
Physics Experiment:
o
Simple Pendulum (P-46)
Technical background:
T
he philosophy behind NeuLog’s plug and play technology is based on each sensor’s
ability to store its own data due to an internal flash memory chip and micro-controller
in each plastic NeuLog body. This technology allows the sensor to collect and then
store the digital data in the correct scientific units (
o
C,
o
F, Lux, %, ppm, for example).
The sensor is pre-calibrated at the factory. The built-in software in the logger can be
upgraded for free at any time using the provided firmware update.