background image

NEULOG ROTARY MOTION LOGGER SENSOR GUIDE

 

 

 

 

1.

 

Connect the rotary motion sensor directly to the left side of a WIFI-201 (no wires 
required). 

2.

 

Connect a BAT-200 module to the right side of the WIFI-201 module. 

3.

 

Although not required, we recommend plugging the BAT-200 to an outlet using a 
USB to mini USB charger (such as a typical cell phone charger). The  WIFI-201 
module  will  run  for  60-90  minutes  (depending  on  the  sensor)  without  being 
plugged in. 

4.

 

The WIFI-201 can be powered directly using a mini to USB cord and plugging it 
into your computer or a wall charger. Please note this function is only available 
on WIFI-201 modules with the USB icon on the cover. 

5.

 

For further WIFI-201 instructions or the WIFI-201 quick start guide please visit: 

www.NeuLog.com

Choose "Products" on the main menu, 

then choose "WiFi Communication module". 

6.

 

The WIFI-201 indicator lights will flash; take no action until the LED to the far left 
turns blue; this can take up to one minute. 

7.

 

Take your tablet or smart phone, go to the WiFi settings and select the NeuLog 
network (NeuLog0184 for example) which matches the ID found on the back of 
the WIFI-201 module (0184 for example). 

8.

 

Give your device about 20 seconds to connect to the WIFI-201. 

9.

 

Once  the  device  is  connected,  go  to  your  browser  and  type  the  website 

wifi201.com

 into the URL bar, then wait for 30-60 seconds. 

10.

 

You will see a “Control mode” icon in the application, click on it. 

11.

 

The  application  will  then  load  a  new  screen  and  begin  to  auto  detect  the 
sensor(s); this can take a minute. (You can stop the search when the sensor is 
found.) 

12.

 

If the browser 

does not auto detect the sensor(s), select “Search for sensors”. 

13.

 

Once the sensor is found you will see a module box on the left side of the screen 
for the rotary motion sensor. In this box, real time data will be displayed. 

14.

 

Click on the “Module setup” button located in the rotary motion sensor module 
box to change the rotary motion probe settings if need be. 

15.

 

Click on the “Experiment setup” icon to change the experiment settings if need 
be (Experiment duration for example). 

16.

 

To run an experiment and collect d

ata, click the “On-Line experiment” icon, then 

click the "Run experiment" icon. 

17.

 

If you have a newer generation  WIFI-201 (with the USB icon on the cover) this 
can  be  used  as  a  USB-200,  meaning  you  can  tether  the  probes  directly  to  the 
computer using the WIFI-201. To engage operation in this fashion, press 3 times 
on  the  panel  button.  Repeating  this  operation  will  return  the  module  to  WiFi 
mode. 

 

Operation with NeuLog Graphic Display Module (viewer) 

 

Materials needed: 

 

NUL-226 Rotary Motion Sensor 

 

VIEW-101 Graphic Display Module 

 

BAT-200 Battery Module 

 

Procedure: 

1. 

Connect the rotary motion sensor to the left side of the viewer. 

2. 

Connect the BAT-200 module to the right side of the viewer. 

3. 

The VIEW-101 will auto detect the sensor and you will see it appear on the left 
side of the screen. 

4. 

Once the sensor appears it will be monitoring data in real time. 

5. 

To run an experiment and collect data press the run icon (little green person). 

 

Off-line experiments 

 
(Off-line  experiments  are  when  you  do  not  have  a  sensor  connected  directly  to  a 
computer, tablet, smartphone, or NeuLog viewer). 
 

Materials needed: 
 

 

NUL-226 Rotary Motion Sensor 

 

BAT-200 Battery Module 

 

Materials needed to configure your offline experiment: 
 

 

USB-200 Module, WIFI-201 module or VIEW-101 Module 

 

USB to mini USB cable (included with the USB-200 module). 

 

Procedure: 

 
1. 

To determine the  experiment settings, first connect  to  your chosen device  (PC, 
Mac,  tablet,  smart  device)  and  click  on  the  “Off-line  experiment”  icon  after  the 
sensor  search  has  ended.  (For  more  information  on  how  to  change  the 
experiment  settings,  view  the  quick  start  procedure  section  for  your  chosen 
device in this document.) 

2. 

Connect the rotary motion sensor directly to the left side of a charged BAT-200 
module. 

3. 

When  ready  to  collect  data  pre

ss  the  “Start/Stop”  button  on  the  rotary  motion 

sensor, a red light will turn on for the duration of the experiment. 

Содержание NUL-226

Страница 1: ...uter The browser based application can be downloaded for free at www NeuLog com as well as a full application user guide Choose Downloads on the main menu and then choose Software and Application Procedure 1 Install the NeuLog application 2 Connect the USB 200 module to the PC or Mac 3 Connect the rotary motion sensor to the USB 200 module they directly plug together Please note there is no calibr...

Страница 2: ...le box to change the rotary motion probe settings if need be 15 Click on the Experiment setup icon to change the experiment settings if need be Experiment duration for example 16 To run an experiment and collect data click the On Line experiment icon then click the Run experiment icon 17 If you have a newer generation WIFI 201 with the USB icon on the cover this can be used as a USB 200 meaning yo...

Страница 3: ...0 03 Experiment Duration 1 second to 31 days Sensor s features Fully digital data Rugged plastic ergonomic case Rotary motion rotating head piece attached directly to the sensor s body by a durable rubber coated wire Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data Pre calibrated sensing equipment Note NeuLog products ar...

Страница 4: ...y motion sensor s body After use gently wipe away any foreign material from the rotary motion sensor Store in a box at room temperature out of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship The warranty is for a period of 3 years from the date of purchase and does not cover damage of the product caused by improper use abuse or incorrect stora...

Отзывы: