background image

NEULOG VOLTAGE LOGGER SENSOR GUIDE

 

 

 

5. 

For further WIFI-201 instructions or the WIFI-201 quick start guide please visit: 

www.NeuLog.com

Choose "Products" on the main menu, 

then choose "WiFi Communication module". 

6. 

The WIFI-201 indicator lights will flash; take no action until the LED to the far left 
turns blue; this can take up to one minute. 

7. 

Take your tablet or smart phone, go to the WiFi settings and select the NeuLog 
network (NeuLog0184 for example) which matches the ID found on the back of 
the WIFI-201 module (0184 for example). 

8. 

Give your device about 20 seconds to connect to the WIFI-201 module. 

9. 

Once  the  device  is  connected,  go  to  your  browser  and  type  the  website 

wifi201.com

 into the URL bar, then wait for 30-60 seconds. 

10. 

You will see a “Control mode” icon in the application, click on it. 

11.  The  application  will  then  load  a  new  screen  and  begin  to  auto  detect  the 

sensor(s); this can take a minute. (You can stop the search when the sensor is 
found.) 

12. 

If the application does not auto detect the sensor(s), select “Search for sensors”. 

13.  Once  the  sensor  is  found,  you  will  see  a  module  box  on  the  left  side  of  the 

screen for the voltage sensor. In this box, real time data will be displayed. 

14. 

Click on the “Module setup” button located in the voltage sensor module box to 
change the voltage probe settings if need be. 

15.  Click  on 

the “Experiment setup” icon to change the experiment settings if need 

be (Experiment duration for example). 

16. 

To run an experiment and collect data, click on the “On-Line experiment” icon, 
then click the "Run experiment" icon. 

17.  If  you  have  a  newer  generation  WIFI-201  module  (with  the  USB  icon  on  the 

cover)  this  can  be  used  as  a  USB-200,  meaning  you  can  tether  the  probes 
directly to the computer using the WiFi-201. To engage operation in this fashion, 
press 3 times on the panel button. Repeating this operation will return the unit to 
WiFi mode. 

 

Operation with NeuLog Graphic Display Module (viewer) 

 

Materials needed: 
 

 

NUL-201 Voltage Sensor 

 

VIEW-101 Graphic Display Module 

 

BAT-200 Battery Module 

Procedure: 

 
1. 

Connect the voltage sensor to the left side of the viewer. 

2. 

Connect the BAT-200 module to the right side of the viewer. 

3. 

The VIEW-101 will auto detect the sensor and you will see it appear on the left 
side of the screen. 

4. 

Once the sensor appears, it will be monitoring data in real time. 

5. 

To run an experiment and collect data, press the run icon (little green person). 

 

Off-line experiments 

 
(Off-line  experiments  are  when  you  do  not  have  a  sensor  connected  directly  to  a 
computer, tablet, smartphone, or NeuLog viewer). 
 

Materials needed: 
 

 

NUL-201 Voltage Sensor 

 

BAT-200 Battery Module 

 

Materials needed to configure your offline experiment: 
 

 

USB-200 module, WIFI-201 module or VIEW-101 module 

 

USB to mini USB cable (included with the USB-200 module) 

 
Procedure: 

 
1. 

To determine the  experiment settings, first connect  to  your chosen device  (PC, 
Mac,  tablet,  smart  device)  and  click  on  the  “Off-line  experiment”  icon  after  the 
sensor  search  has  ended.  (For  more  information  on  how  to  change  the 
experiment  settings,  view  the  quick  start  procedure  section  for  your  chosen 
device in this document.) 

2. 

Connect  the  voltage  sensor  directly  to  the  left  side  of  a  charged  BAT-200 
module. 

3. 

When ready to collect data, press the “Start/Stop” button on the voltage sensor; 
a red light will turn on for the duration of the experiment. 

4. 

After the exp

eriment has concluded (the “Start/Stop” button is pressed again or 

the data collection period ends) connect the sensor to your chosen device (you 
can find full instructions in each device’s quick start procedure section). 

5. 

Open the NeuLog application. 

6. 

Click 

the “Off-line experiment” icon. 

7. 

Click the “Load data from sensors” icon.  

8. 

Select which experimental data to upload (5 experimental runs can be stored at 
one time on the NUL-201 voltage sensor). 

 
 
 
 
 
 

Отзывы: