Contents
DF-150 Rotary Electric Encoder
8.3 s
eTTing
The
e
nCoder
Z
ero
p
oinT
The zero position can be defined anywhere in the working sector.
■
Rotate the shaft to the desired zero mechanical position.
■
Select “Set Current Position” as zero by using the relevant
option, and click [Finish].
8.4 J
iTTer
TesT
Perform a jitter test to evaluate the quality of the installation;
the jitter test presents the reading statistics of absolute position
readings (counts) over time. Common jitter should be up +/-
three counts; higher jitter may indicate system noise.