background image

net
w

or

k-elec
tr

onics

.c

om

Multi rate transponder and converter 

for DWDM 

Rev. 0

Flashlink User Manual

MR-TR-3G-D15xx

Содержание MR-TR-3G-D15 Series

Страница 1: ...network electronics com Multi rate transponder and converter for DWDM Rev 0 Flashlink User Manual MR TR 3G D15xx...

Страница 2: ...9 99 Fax 47 33 48 99 98 Email support network electronics com www network electronics com Support Phone 47 90 60 99 99 Revision history Current revision of this document is the uppermost in the table...

Страница 3: ...4 Connector module 11 4 1 Mounting the connector module 11 4 2 Terminal format support 11 5 Module status 13 5 1 GPI Alarm Module status outputs 13 5 2 Front panel Status monitoring 14 6 Flashlink con...

Страница 4: ...al and optical to electrical converter also called add drop It can also be configured as an optical to optical transponder It can perform optical refreshing re clocking and wavelength swapping The mod...

Страница 5: ...meters can be set and monitored via the web and SNMP interface Function Options Laser On or off Electrical input Normal or bypass Telecom data reclocker Bitrate Reclocker 1 Enable or bypass Reclocker...

Страница 6: ...U T G 694 1 for DWDM Max number of channels per fiber 40 within the C band Channel spacing 100GHz Max wavelength drift 0 16nm Temperature range 0 to 40 C Jitter UI Unit Interval 0 135 UI max 270Mbps 0...

Страница 7: ...7 Standards Supported standards for electrical and optical ports SMPTE SMPTE 292M SMPTE 259M C SMPTE 297M SMPTE 305 2M SMPTE 310M SMPTE424M DVB ASI EN50083 9 Additional supported standards for the opt...

Страница 8: ...EQ Cable equalizer ON Cable equalizer Bypass Equalizer mode 3 RCL2 Reclocker ON Reclocker Bypass Reclocker for electrical output 4 R1 5 R2 R2 R1 11 1000Base X 10 STM 16 2488Mbps 01 STM 4 622Mbps 00 ST...

Страница 9: ...g towards the release handle When a Broadcast format support is selected all clock rates for HD SDI SDI and DVB ASI are automatically configured by the module itself Figur 3 3G HD SD SDI Opt to El and...

Страница 10: ...s more than 6 5dBm When all LED are off input power is below 25dBm Optical input power Status LED LOS lock1 LED LOS lock2 LED Laser fail LED More than 6 5dBm Green Green Green Green 7 0dBm to 8 5dBm Y...

Страница 11: ...minal format support The different input and output ports on MR TR 3G can support a number of formats The table below shows which signal formats are supported on the selected terminals Terminal format...

Страница 12: ...OUTPUT 2 Electrical Output Inverted 3GHD SDI HD SDI SDI Transparent Output OPT TX Optical Output Transmitter 3GHD SDI HD SDI SDI DVB ASI SMPTE310 STM 1 opt STM 4 OC 3 opt OC 12 STM 16 OC 48 Transpare...

Страница 13: ...be used for wiring up alarms for third party control systems The GPI outputs are open collector outputs sinking to ground when an alarm is triggered The GPI input laser disable will turn off the lase...

Страница 14: ...pinning Diode State Red LED Yellow LED Green LED No light Status Module is faulty Yellow blinking DWDM laser temperature stabilizing Module is OK Module power is OK Module has no power LOS LOCK1 Loss...

Страница 15: ...MR TR 3G D Rev 0 6 Flashlink control This card uses the FLP 4 0 protocol See separated documents for definition of this protocol network electronics com 15...

Страница 16: ...77 46 194 6 1540 56 45 194 5 1541 35 44 194 4 1542 14 43 194 3 1542 94 42 194 2 1543 73 41 194 1 1544 53 40 194 0 1545 32 39 193 9 1546 12 38 193 8 1546 92 37 193 7 1547 72 36 193 6 1548 51 35 193 5 1...

Страница 17: ...cification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative humidity range 90 non condensing 2 The equipment will operate without damage und...

Страница 18: ...and conditions for the product s covered by this manual follow the General Sales Conditions by Network Electronics AS These conditions are available on the company web site of Network Electronics AS w...

Страница 19: ...X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 This is indicated by the...

Страница 20: ...th LVD 73 23 EEC EMC 2004 108 EEC HARMONISED STANDARDS applied in order to verify compliance with Directive s EN 55103 1 1996 EN 55103 2 1996 TEST REPORTS ISSUED BY Notified Competent Body Report no N...