SPECIFICATIONS

Rated Voltage  . . . . . . . . . . . . . . . . 20-30 VAC, 24 nominal
Rated A.C. Current  . . . . . . . . . . . . 0.050 Amps to 0.75 Amps
 

continuous per output with 

 

surges to 3 Amps Max.

Rated D.C. Current . . . . . . . . . . . . 0 Amps to 0.75 Amps
 

continuous per output with 

 

surges to 3 Amps Max.

Control Range . . . . . . . . . . . . . . . .

Heating:

 

38° to 88°F in 1° Steps 

 

(5° to 30°C in 1° Steps) 

 

Cooling:

 

60° to 108°F in 1° Steps 

 

(16° to 40°C in 1° Steps)

Thermostat Measurement Range . . 28° to 124°F (0° to 48°C)
O.D.T. Displayed Range  . . . . . . . . -50° to 124°F (-48° to 48°C)
Control Accuracy . . . . . . . . . . . . . . ± 1°F at 68°F Accuracy
 

(± .5°C at 20°C Accuracy)

Minimum Deadband . . . . . . . . . . . (between heating and cooling)
 

2°F (1°C)

NOTE:

  This thermostat contains electronic circuitry replacing the 

conventional mechanical anticipator.

DESCRIPTION OF ICONS

SENSOR FAULTS

There are two sensor faults:
1. Internal sensor is shorted.
2. Internal sensor is open.

When the internal sensor is shorted [the sensed temperature 
>= 124°F (48°C)], all equipment is turned off and the following 
icons are flashed on the LCD:

When the internal sensor is open [the sensed temperature 
<= 32°F (0°C)], all equipment is turned off and the following icons 
are flashed on the LCD:

An open condition is ignored the first 20 minutes after powering 
the thermostat to allow the equipment to heat the surrounding 
environment. This will avoid premature deactivation of the 
equipment if the ambient temperature should happen to be 
below 32°F (0°C).

1 (ONE) YEAR LIMITED WARRANTY

NetworkThermostat™ warrants to the original purchaser that 
this product and its component parts will be free from defects in 
workmanship and materials for a period of one year from the date 
of purchase with proof of purchase.

Warranty Limitations

This warranty begins on the date of purchase.

Warranty is Void if:

The date code is defaced or removed.
The product has a defect or damage due to product alteration, 
connection to an improper electrical supply, shipping and 
handling, accident, fire, flood, lightning, or other conditions 
beyond the control of the manufacturer.
The product is not installed according to the manufacturers 
instructions and specifications.
The product has been installed near sources of electromagnetic 
interference (EMI) such as arcing relay contacts.

Owner’s Responsibility

Provide proof of purchase.
Provide normal care and maintenance.
Pay for freight, labor and travel.
Pay for service calls related to product installation.
Return any defective product.

In no event shall the manufacturer be liable for incidental or 
consequential damages.

This warranty gives you specific legal rights and you may have 
others which vary by state and/or province. For example, some 
states and/or provinces do not allow the exclusion or limitation of 
incidental or consequential damages, so this exclusion may not 
apply to you.

The manufacturer’s continuing commitment to quality products 
may require a change in specifications without notice.

Net/X™ RP32-NX Programmable Thermostat meets CA Title 
24 requirements.

This equipment, if installed in strict accordance with the 
manufacturer’s instructions, complies with the limits for a Class B 
computing device pursuant to Subpart J of Part 15 of FCC rules.

Displays clock and vacation

times in program mode

30 minute display

during power failure

High and Low

Sensor Values

(Indicating Faults)  

Adaptive

Recovery

Flashes

when active

Location Of

Icons On LCD

Содержание RP32-NX

Страница 1: ...f electrical interference such as arcing relay contact INTRODUCTION The RP32 NX Programmable Thermostat represents the most advanced solid state microcomputer temperature control on the market today The thermostat incorporates state of the art technology packaged in an extremely low profile designer series case Integrated with the Net X XBus communications port the RP32 NX is positioned to allow e...

Страница 2: ...ility company Add On Dual Fuel Heat Pump Control If needed the thermostat will perform the function of a fossil fuel kit When in this mode the thermostat will turn off the compressor with a call for AUX heat When Switch 1 and Switch 5 are in the ON position the thermostat allows the compressor and the AUX heat to be on simultaneously Random Restart After a power failure the thermostat will delay t...

Страница 3: ...mperature This temperature will be maintained for the pre programmed amount of time To cancel simply press the RESUME button Temporary Override with Keyboard Locked 15 minutes to 8 hours You may change the temperature setting temporarily at any time without affecting the program even though the keypad is locked Press the UP or DOWN buttons The display will show the temperature for the first event ...

Страница 4: ...TES ON OFF LOCKED DIP1 OFF GAS HEAT DIP1 ON HP DUAL FUEL 2 STAGE CONTROL 5F OVERRIDE RANGE NOT USED KEEP OFF EQUIPMENT WIRING DIAGRAM RP32 NX 2 Stage Gas Furnace Air Conditioning HVAC CONNECTIONS Line Voltage 24 Vac Transformer COOL 1 FAN 24 VAC G Note 1 A Yellow R 24V Jumper is on thermostat circuit board and must be removed if thermostat is to be powered over the XBUS network HEAT 1 W1 Y1 COMMON...

Страница 5: ... OFF LOCKED DIP1 OFF GAS HEAT DIP1 ON HP DUAL FUEL 2 STAGE CONTROL 5F OVERRIDE RANGE NOT USED KEEP OFF EQUIPMENT WIRING DIAGRAM RP32 NX 1 Stage Heat Pump Standard Operation HVAC CONNECTIONS COMPRESSOR 1 FAN 24 VAC G O Note 1 A Yellow R 24V Jumper is on thermostat circuit board and must be removed if thermostat is to be powered over the XBUS network AUXILIARY HEAT W1 REVERSING VALVE B Y1 COMMON 1 5...

Страница 6: ... period of one year from the date of purchase with proof of purchase Warranty Limitations This warranty begins on the date of purchase Warranty is Void if The date code is defaced or removed The product has a defect or damage due to product alteration connection to an improper electrical supply shipping and handling accident fire flood lightning or other conditions beyond the control of the manufa...

Отзывы: