18

Maintenance Mode  (Cont'd)
Function: 

              Keystroke:

Move OSD menu to the left

Make OSD menu taller

Make OSD menu shorter

Activate security features.

Present only when security is
available but not active.

Enter Administration Mode.
Option present only when administrator
is logged in.

Log current user out and return
to User Login Mode.

Save OSD window parameters
for the port

Return to Command Mode

NOTE:  Based on different scan rates, the OSD window may appear in different areas of the monitor as different CPU
ports are selected.  The Maintenance Mode functions allow placement of the window in a particular area of the monitor
and the window will return there when the UNIMUX-USBV-4O USB KVM switch is reconnected to that particular CPU
(provided the parameters are saved before exiting Maintenance Mode).

Search Mode

Search Mode is enabled by typing any alphabetical or numeric characters while in the Command Mode menu (see page 13).

Search Mode allows the user to enter and maneuver through a list of CPU names. The CPU name best matching the characters
typed is selected. The list of CPUs may also be searched for a specific (or similar) name.  The following commands are valid when
the search option has been invoked from Command Mode.

Function: 

   Keystroke:

Erase previous character
in search name

Add a character to the search
string and select the best
matching CPU name

Exit Search Mode, return to
Command Mode

Backspace

A-Z

0-9

(Type any alphabetical or numeric character)

Esc

T

S

A

Esc

Enter

NOTE: If activating security features, the user will be
prompted for a “Y” (yes) or “N” (no) to confirm the menu
choice, at which point the user will be asked for a
username and password before continuing.   Only the
administrator can activate the security features.

Q

(Only displayed when security is active)

 

Enter

or

Содержание NTI UNIMUX UNIMUX-USBV-4

Страница 1: ...4 2 4 2 Port USB KVM Switch INSTALLATION USER GUIDE MAN026 Rev Date 8 19 2003 NTI NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www nti1 com R UNIM...

Страница 2: ...2003 by Network Technologies Inc All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photoco...

Страница 3: ...ration Mode 9 Administrator Password 10 User Name List 10 Edit User 11 Alternate Command Hot Key 12 Command Mode 12 Scan Mode 14 Broadcast Mode 14 Normal Mode 14 Edit Mode 14 Change Settings 15 Broadc...

Страница 4: ...0 Figure 8 Edit the user access list 11 Figure 9 User level Command Mode 12 Figure 10 Additional Command Mode options 13 Figure 11 Change Setting menu 15 Figure 12 Select ports for broadcasting 16 Fig...

Страница 5: ...ollwheel NTI USB SUN Adapter USB Hub Mouse trak track ball Logitech Kensington and Microsoft Wheelmouse or Trackball on Mac CPUs with special drivers OSD Version only Logitech Cordless Elite Duo keybo...

Страница 6: ...n of USB device cables from CPUs 9 USB DEVICES USB type A female connectors for connection of user USB device s 10 DDC button for manual update of DDC information between the monitor and the CPU s att...

Страница 7: ...UNIMUX USBV 4 USB KVM switch Be sure to tighten the two screws on the monitor cable connector to the UNIMUX USBV 4 USB KVM switch securely Note If the DDC Support option is installed a monitor with th...

Страница 8: ...he ports labeled CPU 2 and VIDEO 2 CPU 3 and VIDEO 3 etc Figure 2 Connect a CPU U S B T y p e B F e m a l e C o n n e c t o r U S B T y p e A F e m a l e U S B T y p e A M a l e U S B V E X T x x M M...

Страница 9: ...any touch switch on the front panel of the KEEMUX USBV xU USB KVM switch will connect the corresponding CPU to the monitor and input devices Holding down any front panel touch switch for more than 2 s...

Страница 10: ...rt to connect To a WINDOWS or SUN CPU Exit Command Mode Ctrl ACCENT KEY P Pxx would be P01 P02 etc 0 9 x 0 9 x CHORDED SEQUENCE PRESS CONSECUTIVELY AND KEEP KEYS PRESSED UNTIL ALL ARE PRESSED PRESS CO...

Страница 11: ...to configure the UNIMUX USBV 4 USB KVM switch to emulate a specific international Sun keyboard regardless of what actual keyboard is connected This is recommended when the CPU needs the layout code i...

Страница 12: ...the OSD will locate it HELP screens assist with all OSD functions Note The optional OSD control feature is only available on the 4 port switch Security Option The security option in the OSD Control of...

Страница 13: ...r name password Submit user name password Exit USER LOGIN and return to previous mode This function is only available if security is not currently enabled ADDITIONAL OSD MODES AVAILABLE WITH SECURITY...

Страница 14: ...a Yes or No confirmation Return to Administration Mode User Name List To enter the User Name List press U from the Administration Mode menu The User Name List see Fig 7 enables the administrator to se...

Страница 15: ......

Страница 16: ...ONS Command Mode In order to control the switch with the keyboard Command Mode must be enabled To enable Command Mode from the keyboard Press All the status lights on the keyboard will illuminate to i...

Страница 17: ...s name that matches best Switch to a selected port Update Configuration Display port information Exit Command Mode S Ctrl E Ctrl M Ctrl F1 End Enter Home Esc B Ctrl T Ctrl A Z 0 9 Type any alphabetica...

Страница 18: ...n dwell time See Change Settings Menu on page 15 for configuring the scan dwell time NOTE The scan dwell time set by the user only effects that user and has no effect on other switch users NOTE The ke...

Страница 19: ...de Configuration Go to Scan Mode Configuration Go to Language Selection Menu Option only available if the administrator is logged in Change the scan dwell time period Configure ports for MAC or non MA...

Страница 20: ...st checked box the corresponding port is in the broadcast list The user can toggle the state of the selected check box by pressing Spacebar or clicking the left mouse button press S to check all of th...

Страница 21: ...th all the ports numbers preceded by a check box will be displayed in the window unchecked box the corresponding port is set as connected to a non MAC CPU checked box the corresponding port is set as...

Страница 22: ...Mode Search Mode Search Mode is enabled by typing any alphabetical or numeric characters while in the Command Mode menu see page 13 Search Mode allows the user to enter and maneuver through a list of...

Страница 23: ...main menu will cause a window to open The window will show the name of the port and its position in the system structure level by level This is most useful when cascading switches for Cascading see p...

Страница 24: ...nality Full functionality except Application Key Apple Pro Keyboard Extra keys emulation Extra Keys not supported Eject Mute Volume Volume Full functionality Sun Mouse Full functionality Full function...

Страница 25: ...VM switch to emulate a specific international Sun keyboard regardless of what actual keyboard is connected This is recommended when the CPU needs the layout code i e a SUN CPU and the keyboard doesn t...

Страница 26: ...th Command Mode Note The UNIMUX 4 port USB KVM switch must have OSD installed to use cascading Note Cascading is not an option in the UNIMUX USBV 2 2 port USB KVM switch Figure 16 Cascaded UNIMUX USBV...

Страница 27: ...t do not get connected to the master can be connected to by users Users connected to a slave downstream from the master will control only the CPUs directly connected to that slave switch i e users 5 a...

Страница 28: ...n n e r D r i v e A u r o r a O h i o 4 4 2 0 2 3 3 0 5 6 2 7 0 7 0 w w w n t i 1 c o m N T I R U S B D E V I C E S M O N I T O R V I D E O 1 V I D E O 2 V I D E O 3 V I D E O 4 R E A R V I E W O F M...

Страница 29: ...age 8 DDC SUPPORT OPTIONAL DDC information allows the CPU to automatically select the optimal resolution for the monitor by receiving at power up information from the monitor concerning its resolution...

Страница 30: ...ard and mouse from the UNIMUX USBV 4 USB KVM switch and reconnect them reboot the CPU If the NTI UNIMUX USBV 4 USB KVM switch still seems work improperly help may be found in the Frequently Ask Questi...

Отзывы: