NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 

 

72

 

 

5.8 TERMINAL Connector Pin Assignments

 

 

 
Serial Port (Serial 2) Connector Pin Assignments 
 (RS232C 9-pin connector) 

Pin 

Signal 

Mnemonic Direction 

Data carrier detect

 

DCD In

 

Receive data

 

RxD In

 

Transmit data

 

TxD Out

 

Data terminal ready

 

DTR Out

 

Signal ground

 

SGND

 

Data set ready

 

DSR In

 

Request to send

 

RTS Out

 

Clear to send

 

CTS In

 

 

 
 
 

Printer Port Connector Pin Assignments 
 (Compatible with the IBM PC parallel port) 

Pin 

Signal 

Mnemonic Direction 

-Strobe

 

Out

 

Data bit 0

 

Out

 

Data bit 1

 

Out

 

Data bit 2

 

Out

 

Data bit 3

 

Out

 

Data bit 4

 

Out

 

Data bit 5

 

Out

 

Data bit 6

 

Out

 

Data bit 7

 

Out

 

10 

-Acknowledge

 

In 

11 

Busy

 

In 

12 

Paper end

 

In 

13 

Slct

 

In 

14 

-Auto feed XT

 

Out 

15 

-Error

 

In 

16 

-Init

 

Out 

17 

-Slctn

 

Out 

18-25 

Ground

 

Out 

 

 

Ethernet Connector Pin Assignments  
(RJ45 8 pin female connector) 

Pin 

Signal 

Direction 

Tr

 

Out

 

Transmit -

 

Out

 

R

 

In

 

Receive -

 

In

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1

Mating Face
of 9D Male

2

3

4

5

6

7

8

9

R

8
-

T

7
+

R

6
-

T

5
+

R

4
-

T

3
+

R

2
-

T

1
+

Mating face of an RJ45 Female

SUB-D 25

female connector

1

14

25

13

Содержание NTI SERIMUX-SECURE 8

Страница 1: ...S16 8 Rack Mount Console Terminal Drawer with Console Switch Installation and Operation Manual RACKMUX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora...

Страница 2: ...in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Dr...

Страница 3: ...ministrator 12 3 1 2 Port List 13 3 1 3 Port Settings 14 3 1 3 1 Port serial settings 16 3 1 3 2 Modem settings 18 3 1 3 3 Port data buffer 19 3 1 4 User List 20 3 1 5 User Settings 21 3 1 5 1 Port ac...

Страница 4: ...Setup for LPD 61 4 6 3 LPD printing 62 4 6 4 Setup for TFTP 62 4 6 5 TFTP Printing 62 4 7 On Screen Display OSD 63 4 7 1 Standard Controls 63 4 7 2 OSD Control Menu 63 4 7 2 1 OSD Main Menu 63 4 7 2...

Страница 5: ...re 17 Administrator s Advanced settings menu 23 Figure 18 Firmware menu 24 Figure 19 The SERIMUX is waiting to save its firmware 25 Figure 20 A user with limited host port access 26 Figure 21 User mai...

Страница 6: ...ver session is preserved by the terminal Terminal sessions can be switched via hot keys When using the Ethernet telnet connection the Terminal Drawer can be connected to multiple servers via an Ethern...

Страница 7: ...erial console are connected to user ports The SERIMUX Console Switch supports two operator levels user and administrator Users login at user ports and connect to serial devices attached at host ports...

Страница 8: ...Serial cable with at least one RJ45 male end for connection to the Console Switch from each device to be connected See Interconnection Cable Wiring Method on page 29 for cable pinout Note In order to...

Страница 9: ...Lock keyboard feature is ON 10 Fn LED illuminates when the number pad features are enabled 11 Keyboard for manual data entry and computer control 12 LCD Display for viewing the video signal from the...

Страница 10: ...the top holes in the front bracket flanges line up with the holes marked in step 1 Secure the front brackets on the drawer to the front cabinet rails using 10 32x3 4 screws and cage nuts supplied Be...

Страница 11: ...communication equipment DCE i e modem and data terminal equipment DTE i e CPU each having different connector pin assignments The cable adapters see Materials on page 3 make the proper connections 2 I...

Страница 12: ...UX may be directly connected to PC using a CAT5 Crossover cable See page 67 for specifications 1 5 Power Up The RACKMUX 1 Connect the AC adapter to a power source 2 Using the key unlock the drawer and...

Страница 13: ...n the ALT key and press the Esc key to enter Setup mode When entering Setup any text on the screen temporarily disappears and the main SETUP directory appears See Figure 5 When leaving the Setup mode...

Страница 14: ...ettings are not saved before exiting Setup any new selections will be lost when the RACKMUX is powered down To save Setup selections depress the Spacebar to change the save field at the right side of...

Страница 15: ...NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 10 2 To connect to an attached CPU enter the number of the port the CPU is connected to and press Enter Figure 6 Startup Accessible host list...

Страница 16: ...RIMUX supports 2 operator levels administrator and user each with separate password protection for security The administrator logs in using an administrator password see next page for login procedure...

Страница 17: ...dministrator main menu will appear for user ROOT on port 0 Note This will only enter the administrator mode if the administrator password has not yet been changed from NTI FYI If SERIMUX is not at ini...

Страница 18: ...f another port Pxx connected to that port If the administrator is logged in Adm will be displayed U H Port type User or Host Mdm Modem connection status Y if modem is connected if not BaudRate Port tr...

Страница 19: ...based on the administrator s timeout setting not based on the user s timeout setting If two ports are connected to each other and one port has a lower timeout setting than the other the lower setting...

Страница 20: ...trator consoles Reset Port settings to default Restores factory default port settings A confirmation Y will be required When 3 is pressed to change the in band disconnect sequence the choices provided...

Страница 21: ...alues 3 1 3 1 2 Data bit The data bit number can be 5 6 7 8 except for port 0 7 or 8 To modify the data bit number press 2 then the bit number 5 6 7 8 3 3 1 3 Stop Bit The stop bit number can be 1 2 1...

Страница 22: ...en a modem is attached to the port the DTR line will be pulsed on port disconnection disregarding this parameter value To modify the DTR line behavior on port disconnection press 8 then H or L or P re...

Страница 23: ...try the default values first refer to the manual s for the modems otherwise Figure 12 Modem settings menu The administrator can initialize a modem attached to a SERIMUX port or disconnect the modem T...

Страница 24: ...dministrator can see the last 1016 characters received and transmitted to from any port This way the administrator can verify that data was transferred properly between ports Figure 13 Port data buffe...

Страница 25: ...bled Adm Displays if user has administrative rights Y yes no Port access Displays what ports the user has access to Log Identifies what port the user is logged into if any Con Identifies what port the...

Страница 26: ...s 0 never Administrator privileges Enable administrative privileges for user Y to enable any other character to disable Port access Define ports user has access to Displays user s Port access list Fig...

Страница 27: ...to memory press asterisk to start the paste function Three options are available Option Description Y apply the settings in memory to the current user shown A apply the user settings in memory to all...

Страница 28: ...a login by a valid user with access rights will be required 3 1 6 1 Change administrator password For security purposes the administrator should change the factory default administrator password to a...

Страница 29: ...ailable at this time 3 Save current firmware Save present firmware in SERIMUX to binary file 3 1 6 2 1 Load new firmware To upgrade the firmware that controls the Console Switch as soon as improved ve...

Страница 30: ...col receive the binary file for example the HyperTerminal for Windows Transfer Receive File command to transfer the SERIMUX firmware to a binary file When saving the file choose a directory to place t...

Страница 31: ...ust press Spacebar or Enter after power ON the TERMINAL or opening the connected terminal emulator After login the user may connect to an allowed host port or view host status and parameters The user...

Страница 32: ...ossible Function Keystroke Connect to host port 1 xx Enter where xx is the port index number Display Accessible host list 2 Enter Display accessible host and user ports and info about each 3 Enter Log...

Страница 33: ...to the port Usr Hst Port type user or host Modem Yes if modem is attached if not BaudRate Receiving and transmitting speed of the port Serial Character size parity and stop bit number Flow Defines flo...

Страница 34: ...mber of functions are possible 3 2 4 1 Terse mode commands Connect to port Send or type in C xx Enter where xx is the port index number The answer will be OK CR LF LF FF If an error occurs i e the por...

Страница 35: ...login the administrator to a port other than port 0 the administrator must first configure the desired port as a user port see page 15 By default all ports other than 0 are configured as host ports 3...

Страница 36: ...range Ctrl Q 17 Xoff character any ASCII nonprintable character 0 31 range Ctrl S 19 Inter character delay except port 0 no delay allowed on port 0 1 60 milliseconds none None Line break receive allow...

Страница 37: ...er changes into memory before returning the terminal to the normal operating mode Settings changed will effect the operating environment until the TERMINAL is powered down Setting changes will only be...

Страница 38: ...es the terminal to clear the screen when executing a command to change the number of columns Screen Saver OFF 1 2 3 4 5 6 Sets the screen saver to activate after the specified number of minutes Page L...

Страница 39: ...event loss of data Key Code sets the terminal to send normal ASCII characters ASCII or PC type scan codes for every key up down Scan Scan is only required for the PC Term personality Num Start ON OFF...

Страница 40: ...line of periods that mark each column position 1 A tab stop in columns 2 through 78 is shown as a T in the upper line of periods 2 A tab stop in columns 79 through 132 is shown as a T in the lower li...

Страница 41: ...IP address is used to communicate with other networks If a gateway is not being used this option should be blank Remote IP 0 B Address are for any remote CPU or devices that the terminal will communic...

Страница 42: ...ank will be used to map monochrome attributes to color Color Association OFF ON Table 5 Color Setup Menu Option ASCII NOT WY325 WY325 VTXXX ANSI CONSOLE Background The whole data area of the screen wi...

Страница 43: ...erline and intensity 2 3 Underline intensity 2 and reverse or blank 1 Cyan Black Red Black Magenta Black Blue Black Black White Black Red Black Magenta Black Blue 3 Normal Reverse or blank 1 Intensity...

Страница 44: ...2 Intensity 2 and reverse or blank 1 Underline Underline and reverse or blank 1 Underline and intensity 2 3 Underline intensity 2 and reverse or blank 1 White Black Yellow Black Blue Black Cyan Black...

Страница 45: ...low scrolling rate CTRL SHIFT Home cursor and clear page CTRL SHIFT HOME Display page 0 CTRL 0kpd Display page 1 CTRL 1kpd Display next page or active other window 4 PAGE DOWN Display previous page or...

Страница 46: ...found at the end of Table 8 on page 46 Table 8 Commands Supported in ASCII Personalities Command Native Wyse ADDS TVI PC FUNCTION Mode WY 50 VP A2 910 925 Term Monitor Mode Monitor mode on ESC U Same...

Страница 47: ...CTRL Y Conceal answerback message ESC c Same ENH Send answerback message ESC c Same ENH Turn answerback mode off ESC e SP Same ENH Turn answerback mode on ESC e Same ENH Controlling the Terminal and K...

Страница 48: ...isplay off ESC 0 Same CTRL W Cursor display on ESC 1 Same CTRL X 25th line display off ESC e Displaying the Message Fields Extended status line on ESC a Same ENH Standard status line on ESC b Same ENH...

Страница 49: ...window down in page ESC w F Same Redefine screen as one window ESC x Same Redefine screen as one window ESC x 0 Same and clear pages Display Attributes Assign display attribute to a ESC A mf attr Sam...

Страница 50: ...ESC 9 Received CR mode on ESC e 5 Same ENH ENH ESC 8 Autopage mode off ESC d Same ENH ESC w Autopage mode on ESC d Same ENH ESC v Autoscrolling mode off ESC N Same ENH Autoscrolling mode on ESC O Same...

Страница 51: ...unprotected page to ESC attr ENH ENH display attribute Clear unprotected page to spaces ESC Y Same ESC k Same Same from cursor Clear unprotected page to nulls ESC y Same ENH Same Same from cursor Cle...

Страница 52: ...ESC d CTRL T CTRL T Bi directional mode on ESC d CTRL CTRL R Auxiliary receive mode off ESC d SPACE Auxiliary receive mode on ESC d Set print terminator ESC p ESC p Define delimiters ESC x ESC x Chara...

Страница 53: ...nderline reverse blink invisible Underline reverse blink invisible bank Font Bank a bank Font Bank a 0 Font bank 0 2 Font bank 2 1 Font bank 1 3 Font bank 3 a Holds predefined character set baud Baud...

Страница 54: ...ard Style key Enhanced PC key Enhanced PC key Enhanced PC SPACE ESC SHIFT TAB RETURN SHIFT ESC BACKSPACE SHIFT RETURN TAB SHIFT BACKSPACE HOME SHIFT HOME 3 SHIFT 6 SHIFT DELETE s ENTER kpd R PRINT SCR...

Страница 55: ...5 46 M 70 e 94 23 6 47 N 71 f 95 24 7 48 O 72 g 96 DEL RUB c Native codes also recognized in WY 50 TVI 910 925 and PC Term personalities and in ADDS VP A2 personality absolute cursor addressing lll On...

Страница 56: ...alette 0 Palette 0 4 Palette 4 8 Palette 8 1 Palette 1 5 Palette 5 9 Palette 9 2 Palette 2 6 Palette 6 Palette 10 3 Palette 3 7 Palette 7 parity Parity Bits parity Parity Bits 0 None 2 Mark 1 Odd 3 Ev...

Страница 57: ...Dim UL Blink UL Dim Blink UL Rev UL Rev Dim UL Rev Blink UL Rev Dim Blink h i j k x y z Underline UL UL Dim UL Blink UL Dim Blink UL Rev UL Rev Dim UL Rev Blink UL Rev Dim Blink 4 5 ANSI Command Guide...

Страница 58: ...0 h Same Display screen CSI 30 l Same Display status line CSI 31 h Same Blank status line CSI 31 l Same Screen saver CSI 32 h Same Screen saver off CSI 32 l Same Cursor steady nonblinking CSI 33 h Sam...

Страница 59: ...ttribute 0 Normal all attributes off 25 Blink off 1 Bold blank off 27 Reverse off 4 Underline 28 Blank off 5 Blink 30 Black character 7 Reverse 31 Red character 8 Blank bold off 32 Green character 22...

Страница 60: ...Move cursor down n lines CSI n B or CSI n e Same Move cursor right n columns CSI n C or CSI n a Same Move cursor left n columns CSI n D Same Move cursor down cursor n line to column 1 CSI n E Same Mov...

Страница 61: ...r Same t Top line number b Bottom line number optional if omitted treated as bottom screen line Controlling Tabs Clear tab stop at cursor CSI 0 g or CSI 2 W CSI 2W Clear all tab stops CSI 3 g or CSI...

Страница 62: ...5 S_F5 L C_F5 X C_S_F5 5 F6 A S_F6 M C_F6 Y C_S_F6 6 F7 B S_F7 N C_F7 Z C_S_F7 7 F8 C S_F8 O C_F8 C_S_F8 8 F9 D S_F9 P C_F9 C_ S_F9 9 F10 E S_F10 Q C_F10 C_ S_F10 F11 F S_F11 R C_F11 C_ S_F11 F12 G S_...

Страница 63: ...at cursor ESC 5 Same Send answerback message CTRL E Same Suspend transmission CTRL S Same Resume transmission CTRL Q Same More Terminal Control Commands Display screen adjustment pattern ESC 8 Same S...

Страница 64: ...om the keyboard press CTRL SHIFT 1 use the 1 on the numeric keypad 3 In VT52 or VT100 modes displays checkerboard character 4 5 2 VT52 Command Guide Table 10 VT52 Mode Escape Sequences Command VT52 Mo...

Страница 65: ...t print the data file immediately upon receiving it the print option specified in the control file cannot take affect To install the printer server function of Ethernet Print Terminal the first step i...

Страница 66: ...es to be able to read from or write to the directory e g If it works on a BSD UNIX host and makes the directory usr spool ETPS1 created in step 3 available then follow these three procedures chown dae...

Страница 67: ...e BSD UNIX system run the setup procedure under Setup for LPD on page 61 Otherwise run the Setup for LPD omitting step 6 4 6 5 TFTP Printing Before using TFTP printing the Ethernet Print Terminal need...

Страница 68: ...is highlighted pressing the Menu button will select it Figure 26 OSD Controls The Select button is used to make selections within the OSD menus when the OSD menu is ON When the OSD menu is OFF the Se...

Страница 69: ...With either the RED GREEN or BLUE sections highlighted use the Up or Down arrow to move between them press the Select button to choose the option to adjust Then use the Up or Down Arrow to adjust the...

Страница 70: ...r can be idle before the OSD menu automatically exits adjustable from 10 to 60 seconds LANGUAGE the language that the OSD menus will be presented in With the item highlighted use the Up or Down arrow...

Страница 71: ...Fn key This section will describe which keys have multiple functions and how to enable them Figure 27 Keyboard Layout ESC F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 NUMLCK PRT SC INSERT DELETE SYS RQ PAU...

Страница 72: ...e Fn and NumLock LEDs illuminated pressing some standard keys will result in displaying characters as indicated in the chart below Table 11 Number Pad Keys Standard Key Displayed when NumLock is ON Fu...

Страница 73: ...aracter matrix 7x12 dot matrix in 10x16 cell with 3 dot descenders Screen size 80x25 Page length 1 2 or 4 screens multiple screen page length reduces maximum number of possible telnet sessions Cursor...

Страница 74: ...SUN and Cisco RJ45 console port configurations enabling CAT 5 cabling without pinout concerns Three DB 25 and one DB 9 adapters come in the package A DB 25 male a DB 25 female and a DB 9 adapter supp...

Страница 75: ...s RJ45 Signal DB 25M Signal 1 CTS Connected to 4 RTS 2 DSR 5 DCD Connected to 20 DTR 3 RxD Connected to 2 TxD 4 GND Connected to 7 GND 6 TxD Connected to 3 RxD 6 DCD 7 DTR Connected to 8 DSR 8 RTS Con...

Страница 76: ...ed to 5 CTS DB 25 Male Modem Adapter NTI P N DB25M RJ45F C DB 25 Male Modem to RJ45 Pin Assignment RJ45 Signal DB 25M Signal 1 CTS Connected to 5 CTS 2 DSR Connected to 6 DSR 3 RxD Connected to 3 RxD...

Страница 77: ...Compatible with the IBM PC parallel port Pin Signal Mnemonic Direction 1 Strobe Out 2 Data bit 0 Out 3 Data bit 1 Out 4 Data bit 2 Out 5 Data bit 3 Out 6 Data bit 4 Out 7 Data bit 5 Out 8 Data bit 6...

Страница 78: ...IN Front View of RACKMUX T15 RS16 Slotted holes for securing terminal drawer to rack 15 LCD Display 2 1 9 IN Rear View of RACKMUX T15 RS16 SERIAL PARALLEL ETHERNET 12VDC CONNECTOR RJ45 SERIAL DEVICE C...

Страница 79: ...63 password 11 port access 22 Port List 13 Port serial settings 16 port settings 14 printer connection 6 programmable keys 36 quick start 8 Remote System Control 1 reset button 4 30 ROOT 12 RS 232 Em...

Отзывы: