Page 10
Auto Ping
The AutoPing feature allows iBoot to automatically detect failed equipment and perform a timed
reboot or other power control function (like turning on an indicator or siren). You set any IP address
to be periodically pinged. When iBoot no longer detects a response from the address, the
programmed power control function is actuated.
Use Auto-Ping Locally: Put iBoot next to the device to be monitored and reboot it automatically
when it no longer responds.
Use Auto-Ping Remotely: Put iBoot at a central facility to monitor a remote system and power up an
alert when the remote device no longer responds.
Ping Address: Enter the IP address of the device to be pinged. If using CallerIP, this address must
be allowed.
Ping Frequency: Enter 1 to 999 seconds. The ping will go out to the selected device this often.
Fail Counter: Enter 1-99 times the ping needs to fail consecutively before the selected action is
taken. When the fail count has been reached, the AutoPing action will be triggered.
Action: Select from
None
AutoPing not used
Power On – Latch
Upon triggering, iBoot will power on and remain so until changed via
the web, ibootctl.exe or direct messaging.
Power On – Follow
Upon triggering, iBoot will power on. When the ping response
returns, iBoot will power off.
Power Off – Latch
Upon triggering, iBoot will power off and remain so until changed via
the web, ibootctl.exe or direct TCP/IP control.
Power Off – Follow
Upon triggering, iBoot will power off. When the ping response
returns, iBoot will power on.
Power Cycle
Upon triggering, iBoot will cycle the power. iBoot will wait the Ping
Frequency x Fail Count; if the response does not return, the power
will be recycled again. This will continue until the ping response
returns or Auto Ping is turned off. Make sure your Auto Ping
frequency is longer than the time required to reboot your device.
Power Cycle Once
Upon triggering, iBoot will cycle power one time. It will not cycle
again automatically until the ping response returns and is lost again.
With Auto-Ping operational, the main iBoot page will display the current status of this feature. The
status will be OK to indicate that iBoot is receiving responses to the ping, or that the fail counter has
not yet been exceeded.
If the fail count has been exceeded, the status will change to Triggered. The Trigger Counter
indicates the number of times the Auto-Ping feature has been triggered. A counter reset button is
provided when logging in with the System password.