PWR-RMT-RBT
Remote Power Reboot Switch
Installation and Operation Manual
ENVIROMUX
®
Series
NETWORKTECHNOLOGIESINCORPORATED
Tel:330-562-7070Fax:330-562-1999
1275 Danner DrAurora, OH 44202
www.networktechinc.com
NTI
R
Страница 1: ...PWR RMT RBT Remote Power Reboot Switch Installation and Operation Manual ENVIROMUX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www networ...
Страница 2: ...75 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the...
Страница 3: ...Man095 Rev 10 23 07...
Страница 4: ...Man095 Rev 10 23 07...
Страница 5: ...pter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this product where...
Страница 6: ...bilities iBoot features several other means to operate automatically or under computer control Auto Ping The Auto Ping feature allows the switch to automatically detect failed Dual equipment and perfo...
Страница 7: ...lectrical standards If the device to be powered uses an IEC320 receptacle and detachable power cord an IEC to IEC extension cord can be used The iBoot can be connected to a power strip to allow simult...
Страница 8: ...work with iBoots on the same local subnets as the iBoots Once the iBoot Setup Utility is run click on Discovery to display all the iBoots on your network New iBoots will display with the name Set Loca...
Страница 9: ...Boot Once an IP address is assigned you must check the DHCP server or use the iBoot Setup Utility to see what address is assigned to iBoot If you set the IP address using another method the address be...
Страница 10: ...eturns host not responding 4 times then the address has not been programmed properly The process must be run within two minutes of powering up the iBoot and not have been set by a DHCP server Check th...
Страница 11: ...abort a power cycle click on either Power On or Power Off buttons iBoot will assume the status selected If the Auto Ping or Heartbeat Features are in use then the page will also display the current s...
Страница 12: ...If the new port is 9105 then use address http 192 168 1 254 9105 CallerIP 1 and 2 CallerIP provides IP address filtering to insure only authorized personnel access the iBoot You can set two IP address...
Страница 13: ...ibootctl exe or direct messaging Power On Follow Upon triggering iBoot will power on When the ping response returns iBoot will power off Power Off Latch Upon triggering iBoot will power off and remain...
Страница 14: ...t not to the Setup functions When this password is used the main screen will not have a link to Setup The System Password allows access to both the Main Screen and the Setup Screen The default for bot...
Страница 15: ...t Confirmation The heartbeat can be generated in any of several ways A Windows executable program that will run as a tray applet that will transmit heartbeats at a steady interval to an iBoot A Window...
Страница 16: ...the heartbeat returns and is lost again Using Heartbeat Monitor With Heartbeat operational the main iBoot page will display the current status of this feature The status will be OK to indicate that i...
Страница 17: ...ir responses Command Format All of iBoot s commands follow the following format esc password esc action cr esc ASCII Escape character 1b hex or 27 decimal password The 1 to 10 character Power Control...
Страница 18: ...0 A Max at 210 240 VAC Compliance UL cUL UL60950 Listed I T E File No E225914 CE Directives 89 336 EEC 92 31 EEC and 93 68 EEC EN 60950 3rd Edition EN 55022 1998 Class B FCC Part 15 Class B Network Du...