NTI XTENDEX DVI FIBER OPTIC EXTENDER
7
TROUBLESHOOTING
The monitor displays only black screen.
Ensure that all plugs and jacks used by external power supplies are firmly connected. Ensure the blue LED is illuminated.
Ensure that the DVI ports are firmly plugged-in to the PC and display.
Ensure that the transmitter and receiver modules are connected correctly to the PC and display, respectively.
Check if the PC and display are powered ON and properly booted.
Reset the system by un-plugging and re-plugging the transmitter DVI port or receiver DVI port, or by un-plugging and re-
plugging the power cord plugs of the transmitter and receiver modules.
Re-boot up the system while connecting the optical DVI extension module.
Screen is distorted or displays noises.
Check if the graphic resolution is properly set. Go to the display properties of Windows and check the settings.
Ensure that the resolution is set to no greater than 1920x1200 at 60Hz refresh ratio.
Reset the system. Disconnect and reconnect the optical DVI cables or 5V power adapters.
For technical service,
contact Network Technologies Inc at
(800) 742-8324
(800-RGB-TECH) or
(330) 562-7070
or visit our
website at
http://www.networktechinc.com
PRODUCT SPECIFICATIONS
Fiber Optic DVI Extension Modules
D V I s t a n d a r d c o m p l i a n c e
S u p p o r t s D V I 1 . 0 , f u l l y implemented by fiber-optic communication
and DDC2B by virtual DDC.
Video Connectors
DVI-D Single-link
Maximum Resolution
1920x1200 at 60Hz
Extension Limit (multi-mode fiber)
3280 feet (1000 meters)
Graphic transmission bandwidth
Supports up to WUXGA at 60Hz, or 1.65Gbps bandwidth
Fiber-optic connection
one SC receptacle so as to be connected with one SC simplex multi-mode
fiber, having 9(8)/125ìm or 62.5(50)/125ìm core.
DDC connection
Virtual DDC by Auto EDID programming
Environmental Conditions
Operating temperature
32°F-122°F (0°C to 50°C)
Storage temperature
-4°F to 158°F (-20°C to 70°C).
Humidity
5% to 85%
non-condensing RH
General
Transmitter and Receiver Power
100V or 240V at 50 or 60Hz-5VDC/2.0A via AC Adapter (1)
Dimensions WxDxH (In.)
1.6x2.6x0.6