background image

Modular Telecom Router 

 

Rev. 4 

4

 

Router communication 

You gain access to router for communication purposes by connecting either 
the router’s serial port to your computer and/or by using an Ethernet 
connection. 

4.1

 

Serial connection 

Connection can by made trough the serial port(s) of the router; see also 
Chapter 1 for connection details. 
 
The communication parameters are configurable. Please refer to the protocol 
documentation of the appropriate communication/control protocol. 
Example: The protocol parameters of the 

VikinX

®

 Compact routers

 are as 

follows: 
-

 

Bit rate 19200 bit/s 

-

 

Data bits 8 bits 

-

 

Stop bits 1 

-

 

Parity: No parity 

 
For further detail concerning this protocol, please refer to the following 
manual: 

VikinX Compact Protocol.pdf

 
The DB9 female connector for the serial port(s) of the router has the following 
pin-out: 
 

Pin # 

RS-232 mode 

RS-422 mode 

Not in use 

Not in use 

2 Tx 

Tx 

3 Rx 

Rx 

Not in use 

Not in use 

5 GND 

GND 

6 GND 

GND 

7 RTS 

Tx + 

8 CTS 

Rx - 

Do Not Connect! 

Do Not Connect! 

 
 

Note that if the standard RS-232 cable specification (DCE) is followed: 

 

a cable with 

Male+Male

 

or

 

Female

 connectors at the cable ends is 

used for Rx/Tx crossed connection, and 

 

a cable with 

Male+Female

 connectors at the cable ends is used for a 

straight through connection. 

 
 

 

25

 

Содержание VikinX T128128-140

Страница 1: ...T3232 140 155M T6464 140 155M T9696 140 155M T128128 140 155M T3232 140 155S T6464 140 155S VikinX Modular 140 155 Mbps Telecom Router Hardware Manual Rev 4...

Страница 2: ...9 Revision history Current revision of this document is the uppermost in the table below Revision Replaces Date Change description 4 3 2007 03 30 Added Materials Declaration and EFUP updated EC Declar...

Страница 3: ...o configure the router and modules 14 3 3 Power Supply module 15 3 3 1 Module insertion 15 3 3 2 Module removal 15 3 3 3 How to connect power to the Modular Telecom Router 15 3 3 4 Status LEDs and Rel...

Страница 4: ...Connecting signal cables to the Modular Telecom Router 27 6 Before calling Network Support 28 7 Serial number overview 29 Notes 30 Materials Declaration and EFUP 31 Materials declaration 31 Environmen...

Страница 5: ...eed performance specification under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range 95 non condensing 2 The equipment will operate...

Страница 6: ...ty The warranty terms and conditions for the Modular Telecom Router follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Network Ele...

Страница 7: ...es The source code for these components and our modifications are available from http labs network electronics com open source You may also send Network Electronics a recordable CD and a self addresse...

Страница 8: ...rear panel VikinX Modular provides all important 3 rd party control interfaces allowing the control of our routers through 3 rd party management software On top of that does the Network Electronics TH...

Страница 9: ...ule DC Supply voltage range 36 72VDC 300W DC Mains connector Screw terminal separate input for each PSU module Alarms Power failure alarm on relay contact closure LED in front and Open Collector to GY...

Страница 10: ...bps Connector 75 ohm BNC female Impedance 75 ohm nominal Return loss 15dB 5 540Mhz Cable equalisation 0 to 300m typical Belden 8281 Electrical signal outputs Connector 75 ohm BNC female Impedance 75 o...

Страница 11: ...Modular Telecom Router Rev 4 Timing adj range 0 20 lines in 1 line steps 11...

Страница 12: ...SU is installed screw terminals not mounted on illustrated router above Serial A1 and A2 RS 232 or RS 422 for external control protocols Serial B1 and B2 RS 232 or RS 422 for external control protocol...

Страница 13: ...Synchronisation signal 1 in out Blackburst composite tri level sync reference input with passive loop through for vertical interval switching VIT 2 Synchronisation signal 2 in out Blackburst composit...

Страница 14: ...he door may be removed for easy access to the modules An important feature of all the modules in the Modular Telecom Router frame is that they are all hot swappable The user does not have to turn off...

Страница 15: ...supply module one must insert the module via the special plastic guide rails into its position Once the module is inserted fix the module by lifting up the handle on the front and pushing it to the u...

Страница 16: ...r supply module that selects mains voltage The mains voltage can be either 110VAC or 230VAC This switch must be set in the correct position depending on the mains voltage on the router s site Failing...

Страница 17: ...card fails and install this CF card on a new SysCon card The router will not notice the difference 3 4 1 Card insertion The frame is equipped with plastic guide rails to align the SysCon cards into th...

Страница 18: ...ase the card by moving the red handle until it is in horizontal position as shown in the figure below Then pull the card out of the sub rack with the red handle 3 4 3 Status LEDs and Reset button Ther...

Страница 19: ...nd software reconfigurations upgrades Medium load on the Controller Low or normal load on the Controller Not applicable Reset button The reset button on the rear side is used to perform a hard reset o...

Страница 20: ...e description earlier in this manual 2 Slide the battery out of its socket and insert the new battery into the socket 3 Insert the SysCon card into its slot according to the description earlier in thi...

Страница 21: ...me as on the SysCon card See Chapter 3 4 3 3 5 4 CF card and battery The Compact Flash CF card and battery are both inserted and or removed in the exact same way as on the SysCon card See Chapter 3 4...

Страница 22: ...the card The tip of the handles enters the hole and the card is locked and proper contact ensured when you hear a click from both handles Note that it may be necessary to press hard when inserting th...

Страница 23: ...on the card is outside their legal range All internal voltages are OK TEMP The temperature of the card is outside its legal range The temperature of the card is OK FAN1 Fan error when the fan speed is...

Страница 24: ...Modular Telecom Router Rev 4 switch must always be in the position towards the card front The switch is for factory use only Reset button Service switches SW4 SW2 24...

Страница 25: ...routers are as follows Bit rate 19200 bit s Data bits 8 bits Stop bits 1 Parity No parity For further detail concerning this protocol please refer to the following manual VikinX Compact Protocol pdf T...

Страница 26: ...onnection 4 3 Ethernet connection The connections follow the standard set by the IEEE 802 3 100BaseTX specification The cables that are to be applied should be CAT 5 CAT 5E standard or better It is th...

Страница 27: ...elecom Router Rev 4 5 Connecting signal cables to the Modular Telecom Router The Modular Telecom Router offers standard 75Ohms BNC connectors for in and outputs All inputs are terminated with 75Ohms P...

Страница 28: ...Warn LED on the SysCon card is RED An abnormal situation has occurred See Chapter 2 If the router has redundant PSU modules check that both modules are properly installed and are working If the route...

Страница 29: ...when contacting Network Electronics ASA for product support Device Part Part Serial number Frame including all static cards Power Supply Module 1 Power Supply Module 2 if included X point Card 1 X poi...

Страница 30: ...Modular Telecom Router Rev 4 Notes 30...

Страница 31: ...s substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 Parts without any of the above mentioned hazardous substances are...

Страница 32: ...b site http www network electronics com Please contact Network Electronics ASA s Customer Support for assistance with recycling if this site does not show the information you require Where it is not p...

Страница 33: ...EEC DIRECTIVES this equipment complies with EN 55103 1 1996 EN 55103 2 1996 EN 60950 1 2006 HARMONISED STANDARDS applied in order to verify compliance with Directive s TEST REPORTS ISSUED BY Notified...

Отзывы: