ASI-IP-GTW User's Manual
Page
74
Table 14. Alarm condition description.
The description of the severity levels of the different alarms are given in
Section 5.2.6.
Alarm Description
Error
source
Bitrate regulation in
progress
The regulation algorithm is working with
bitrate estimation.
This alarm may stay on the first minutes
after tuning to a new IP stream. If the
alarm does not clear, the input stream
may be a variable bitrate stream.
SNTP server
unreachable
Unit is unable to connect to SNTP
server.
There is no SNTP server on the
configured IP address or there is no
contact with the SNTP server due to
network problems.
No sync
No valid ASI input stream detected.
The problem can be related to a
problem with the sending device or the
cable.
Too high
temperature
Internal temperature of unit is too high.
The fans are not working or forced
cooling is required.
Sequence error
Analysis of the sequence number of the
RTP layer indicates that IP frames have
been lost or that they have been
received out of order
Typically this error is generated by
packets being dropped by some
equipment in the network, f.ex when a
link is overloaded.
Defective fan
There is an error with fan of the unit
Hardware problem.
No data received
No data received on Ethernet input for
stream
The most likely error is that there is a
set-up problem where IP address and
UDP port are not correctly configured.
The error can result from an error with
the transmitting unit or an error on the
network.
No lock
The IP receive channel is not able to
find an initial bitrate for the data
received.
The stream contains a PCR PID with an
invalid clock reference.
Data lost
Stream received is incomplete and a
valid ASI output can not be expected
See ‘Sequence errors’. If you have
‘Sequence errors’ but not ‘Data lost’, all
frames are received but they are out of
sequence, or enough data is received
for the FEC engine to correct all lost
frames.
ARP unresolved
IP address not resolved into physical
MAC address.
This error may be caused by wrong
default gateway configured, wrong
unicast IP address on same subnet or
unit on same subnet does not respond.
Ethernet link down
No link on Ethernet layer
No connection on physical layer.
Input buffer
overflow
The total bitrate of the IP input streams
is too high.
There is a configuration error or one of
the sources is generating a too high
bitrate.
Output buffer
overflow
The total bitrate of the ASI input
streams is too high.
There is a configuration error or one of
the sources is generating a too high
bitrate.