Network Appliance VikinX A128128M Скачать руководство пользователя страница 34

EC Declaration of Conformity 

 
 
 
 
 
 
 
 
 
 
 
 

Network Electronics AS 
P.B. 1020, N-3204 SANDEFJORD, Norway 

MANUFACTURER 

AUTHORISED REPRESENTATIVE 
(Established within the EEA) 

Not applicable 

A3232M / A6464M / A128128M 
A3232S / A6464S 

MODEL NUMBER(S) 

Modular Analog Stereo Audio Router 

DESCRIPTION 

LVD 73/23/EEC 
EMC 89/336/EEC 

DIRECTIVES this equipment complies with 

EN 55103-1:1996 
EN 55103-2:1996 
EN 60950-1:2006 

HARMONISED STANDARDS applied in order to 
verify compliance with Directive(s) 

TEST REPORTS ISSUED BY 

Notified/Competent Body  

Report no: 

Nemko 42192 

 

Not applicable 

TECHNICAL CONSTRUCTION FILE NO 

2005 

YEAR WHICH THE CE-MARK WAS AFFIXED 

 

TEST AUTHORIZED SIGNATORY 

MANUFACTURER AUTHORISED 

REPRESENTATIVE 

(Established within EEA) 

Date of Issue 

  

2007-03-27 

 

Place of Issue 

 

Not applicable 

Sandefjord, 
Norway 

Nils B. Sannes 

 

Name  

Quality Manager 
(authorized signature) 

 

Position 

 

 

Содержание VikinX A128128M

Страница 1: ...erer network electronics com VikinX Modular Analog Audio Router Rev 8 VikinX User Manual A3232M A6464M A128128M A3232S A6464S...

Страница 2: ...2008 06 13 Expanded description of how to configure Mono Stereo router s Chapter 3 2 1 7 6 2007 11 06 Added description of how to configure Mono Stereo router s Chapter 3 2 1 6 5 2007 10 26 New front...

Страница 3: ...e router and modules 13 3 2 1 How to configure Mono Stereo routers 14 3 3 Power Supply module 14 3 3 1 Module insertion 15 3 3 2 Module removal 15 3 3 3 How to connect power to the Modular Analog Audi...

Страница 4: ...27 5 Connecting signal cables to the router 28 5 1 Unbalanced signals on the Modular Analog Audio Router 28 6 Before calling Network Support 29 7 Serial number overview 30 Notes 31 Materials Declarat...

Страница 5: ...nteed performance specification under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range 95 non condensing 2 The equipment will opera...

Страница 6: ...nty The warranty terms and conditions for the Modular Analog Audio Router follow the General Sales Conditions by Network Electronics AS These conditions are available on the company web site of Networ...

Страница 7: ...nses The source code for these components and our modifications are available from http labs network electronics com open source You may also send Network Electronics a recordable CD and a self addres...

Страница 8: ...rchitecture meaning that all components are front loaded without any active components on the rear panel VikinX Modular provides all important 3 rd party control interfaces allowing the control of our...

Страница 9: ...r IEC 320 separate input for each PSU module Alarms Power failure alarm on relay contact closure LED in front and Open Collector to GYDA VX Alarms connector RJ45 Safety standards Compliant with CE EN6...

Страница 10: ...uts Type Balanced Connector DB25 female Impedance 10 kohm CMRR 60 dB Max level 23 dBu Electrical signal outputs Type Balanced Connector DB25 female Impedance 66 ohm CMRR 60 dB Max level 23 dBu Gain ad...

Страница 11: ...422 for external control protocols Serial B1 and B2 RS 232 or RS 422 for external control protocols if redundant Syscon is installed Ethernet A 10 100Base T Ethernet bus for external router control E...

Страница 12: ...1 Synchronization signal 1 in out Black burst composite tri level sync reference input with passive loop through for vertical interval switching VIT 2 Synchronization signal 2 in out Black burst comp...

Страница 13: ...n important feature of all the modules in the Modular Analog Audio Router frame is that they are all hot swappable The user does not have to turn off the power in order to remove reinstall replace a m...

Страница 14: ...estart the router and you have a 32x32 Stereo Analog Audio router where the left channel in connected to I O 1 32 on the lower backplane and the right channel is connected to I O 33 64 on the same bac...

Страница 15: ...nnect power to the Modular Analog Audio Router There are two power connectors on the back of the frame Both of these connectors are for AC mains connection Use an IEC 320 connector to connect AC mains...

Страница 16: ...ay contact is normally open and the contact closes on power failure The PSU module A alarm is formed by contact between Pin 3 and Pin 6 Green pair The PSU module B alarm is formed by contact between P...

Страница 17: ...e is a hole above each module slot When the tip of the handle is just below this hole start to push the handle downwards as in the figure The tip of the handle enters the hole and the card is locked a...

Страница 18: ...ard is OK Card has no power or is not inserted correctly Eth Not applicable Full duplex connection Half duplex connection No Ethernet link established check cable Warn Abnormal situation no functional...

Страница 19: ...he router configuration as well as information regarding control panels that are connected to the router is stored in the Compact Flash card on the Syscon card If it is necessary to remove and or inse...

Страница 20: ...useful and requested features for STATUS MONITORING of the Modular Router The GYDA VX provides the user with SNMP agent and TCP IP Web interface allowing monitoring and control of the router from any...

Страница 21: ...The X point cards are inserted according to the labeling on the rear side of the frame 3 6 1 Card insertion To insert an X point card slide the module along the plastic guide rails into its position O...

Страница 22: ...from the system controller on communication channel 1 TEST No special function for internal testing purpose only FAN 2 Fan error when the fan speed is outside its normal range FAN2 is the innermost fa...

Страница 23: ...ry use only The slide switch furthest from the front of the X point card SW4 This switch must always be in the left position as seen from the card front The switch is for factory use only 3 6 5 Gain c...

Страница 24: ...61 1 3 SW261 1 4 SW181 3 68 SW261 3 4 SW261 3 5 SW161 4 69 SW241 4 5 SW241 4 6 SW181 4 70 SW261 4 6 SW261 4 7 SW161 2 71 SW241 2 7 SW241 2 8 SW161 3 72 SW241 3 8 SW241 3 9 SW101 2 73 SW301 2 9 SW301 2...

Страница 25: ...3 45 SW41 4 109 SW121 4 45 SW121 4 46 SW61 4 110 SW141 4 46 SW141 4 47 SW41 2 111 SW121 2 47 SW121 2 48 SW41 3 112 SW121 3 48 SW121 3 49 SW261 2 113 SW101 2 49 SW101 2 50 SW241 1 114 SW81 1 50 SW81 1...

Страница 26: ...ct routers are as follows Bit rate 19200 bit s Data bits 8 bits Stop bits 1 Parity No parity For further detail concerning this protocol please refer to the following manual VikinX Compact Protocol pd...

Страница 27: ...2 connection 4 3 Ethernet connection The connections follow the standard set by the IEEE 802 3 100BaseTX specification The cables that are to be applied should be CAT 5 CAT 5E standard or better It is...

Страница 28: ...d Fostex DB25 Pin Channel Hot Cold GND 1 24 12 25 2 10 23 11 3 21 9 22 4 7 20 8 5 18 6 19 6 4 17 5 7 15 3 16 8 1 14 2 All audio contacts used on the routers are female type 5 1 Unbalanced signals on t...

Страница 29: ...he Warn LED on the Syscon card is RED An abnormal situation has occurred See Chapter 2 If the router has redundant PSU modules check that both modules are properly installed and are working If the rou...

Страница 30: ...mbers when contacting Network Electronics AS for product support Device Part Part Serial number Frame including all static cards Power Supply Module 1 Power Supply Module 2 if included X point Card 1...

Страница 31: ...Modular Analog Audio Router Rev 8 Notes 31...

Страница 32: ...s substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 Parts without any of the above mentioned hazardous substances are...

Страница 33: ...web site http www network electronics com Please contact Network Electronics AS s Customer Support for assistance with recycling if this site does not show the information you require Where it is not...

Страница 34: ...complies with EN 55103 1 1996 EN 55103 2 1996 EN 60950 1 2006 HARMONISED STANDARDS applied in order to verify compliance with Directive s TEST REPORTS ISSUED BY Notified Competent Body Report no Nemk...