Replacing an LRC/ESH/ESH2/ESH4 module
Replacing an LRC/ESH/ESH2/ESH4 module
Removing a module
Assumption about
this procedure
This procedure is based on the assumption that the disk shelf is in a configuration
which fulfils one or all of the following requirements:
◆
It has a single path connection
◆
It is not in a cluster
◆
It does not use synchronous mirroring
Removing a module
To remove a module that is connected to the Fibre Channel loop, complete the
following steps.
Step
Action
1
Put on the antistatic wrist strap and grounding leash.
2
If the disk shelf
connects to a...
Then...
Filer/FAS appliance
Shut down the filer/FAS appliance by
entering the following command at the
console:
halt
Caution
Always use the
halt
command to
perform a clean shutdown.
NetCache appliance
1.
From the Appliance Manager home
page, select the Maintenance tab >
System Control > Halt/Reboot.
2.
Select Halt NetCache.
3
Verify that the LCD display at the front of your NetApp appliance
displays the following message:
Halted