Chapter 3: Replacing Disk Shelf Devices
41
Replacing a disk shelf in a rack
Installing a disk shelf in a rack
Installing a disk
shelf
To install the disk shelf in a rack, complete the following steps.
WARNING
WARNING
You must install each disk shelf with either the two-post telco tray kit or the
four-post rail kit that came in your shipment package. If you choose to mid-
mount the disk shelf, use the mid-mount brackets with the two-post telco
tray kit. Do not ear-mount the disk shelf into a telco-type rack; the disk shelf
will collapse from the rack under its own weight.
Step
Action
1
Verify that your storage controller meets the minimum software
requirements to support the disk shelf. See the
System Configuration
Guide
at
http://now.netapp.com
for more information.
2
Verify that you received the envelope with the disk shelf ID labels.
3
Ground yourself to the system chassis using the grounding leash.
4
Use the rail kit installation flyer in the rail kit box to install the
appropriate rail kits on the rack.
5
Install and secure the disk shelf onto the support brackets and rack.
6
Change the disk shelf ID with the following procedure:
1.
Press the thumbwheel switch on the rear of the disk shelf and use
the + button to raise the number and the - button to lower the
number to a valid ID from 1 through 7.
2.
Power-cycle the disk shelf for the new ID to take effect. The disk
shelf ID display on the front of the disk shelf blinks until you
power-cycle the disk shelf.
3.
Select the correct label from the envelope identified in
attach it to the right flange of the new disk shelf.
7
If you are adding multiple disk shelves on the same loop, repeat
to install the remaining disk shelves.