26
Startup error messages
Startup error messages
POST error messages
POST error
messages
The following table describes the POST error messages that might appear on the
system console of the appliance, if the system encounters environmental, CMOS,
or CPU errors during the POST process.
Note
Always power cycle the appliance when you receive any of the following errors.
If the system repeats the error message, follow the corrective action for that error
message. Also, if any
Processor 2
error messages are displayed, power cycle the
system. If the error message persists, replace the motherboard, as described in
“
Replacing the motherboard
” on page 102.
Error message or code
Description
Corrective action
*Boot DeviceErr
The CompactFlash™ card could not
be found to boot from.
Insert a CompactFlash card.
*Clock bogus. Date reset
The system real-time clock (RTC)
contains an invalid date value. The
system does not boot, but the date is
reset to January 1, 1970, to enable a
subsequent boot.
Reboot the appliance and reset the
date immediately to avoid file
system problems.
*Clock dead
*Clock battery is dead
The system RTC failed and its
battery expired.
Replace the failed RTC battery, or
replace the motherboard.
*Clock error
The system real-time clock (RTC) is
not operating (counting) correctly.
Replace the motherboard.
*Clock reset
The system RTC is not running. The
system does not boot, but the date is
reset to January 1, 1970, to enable a
subsequent boot.
Reboot the appliance and reset the
date immediately to avoid file
system problems.