7
5-5. Wake up ZB11B
When users would like to setup or acquire data from the device which is in sleeping mode, we have to wake
up the device as the following steps:
Step1. Press the
Auxiliary Key
.
Step2. The indicator flashes
green
5 times
when ZB11B is online.
Step3. ZB11B will broadcast the device data to the ZigBee network.
ZB11B would be in active status for 2 minutes for communication.
5-6. Battery
ZB11B will send a low-power report to the ZigBee network when the operating voltage is lower than 3.2V by
default.
The related data:
Power configuration cluster (ID:0x0001)
Battery voltage attribute (ID:0x0020)
The reporting voltage can be adjusted. There are 4 voltages for choosing: 3.5V/ 3.4V/ 3.3V/ 3.2V.
It is recommended that the minimal reporting internal is longer than 3-minute.
5-7. Infrared Sensor Detection and Report
When the infrared sensor detects a movement, ZB11B would send the ON task to the binding device based on
how bright the location is. The light sensitivity can be adjusted by user. After ZB11B sends the ON task, there
will be 2 conditions:
A. No additional movement is detected in 30 seconds → it sends the OFF task to the binding device.
B. Further movement is detected → the infrared sensor will be inactive for 21 seconds (30 seconds x 70%).
In the 22nd ~ 30th second, it sends the OFF task while no additional movement is detected; otherwise,
it goes to condition B again.
Users could change the light sensitivity by adjusting the Light Sensitivity Adjuster.
Clockwise adjustment → Send the task message in
brighter
location
Users could change the detecting sensitivity by adjusting the Sensor Sensitivity Adjuster.
Clockwise adjustment → Higher sensitivity
NOTE
: After ZB11B is turned on, the infrared sensor is not active for 1 minute.