6. Home Automation Clusters for ZB11B

A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by ZB11B.

1.End Point(s)

0x01:

2.Device ID

HA On/Off Switch

0x0000

3.EndPoint Cluster ID

Server side

Client side

Mandatory

Basic(0x0000)

On/Off Switch

(0x0006)

Power configurationr(0x0001)

Identify(0x0003)

Commissioning(0x0015)

Poll control(0x0020)

Diagnostics Cluster(0x0B05)

This lists the attributes of the basic information.

Identifier

Name

Type

Range

Access

Default

Mandatory /

Optional

0x0000

ZCLVersion

Unsigned

8-bit integer

0x00 –

0xff

Read only

0x03

M

0x0001

ApplicationVersion

Unsigned

8-bit integer

0x00 –

0xff

Read only

--

O

0x0002

StackVersion

Unsigned

8-bit integer

0x00 –

0xff

Read only

--

O

0x0003

HWVersion

Unsigned

8-bit integer

0x00 –

0xff

Read only

--

O

0x0004

ManufacturerName

Character

string

0 – 32

bytes

Read only

netvox

O

0x0005

ModelIdentifier

Character

string

0 – 32

bytes

Read only

ZB11BE3E

D

O

Содержание ZigBee ZB11B

Страница 1: ...ZigBeeTM Motion On Off Switch User Manual Motion On Off Switch Model ZB11B 20140109 FW V2 0 HW V1 0 ...

Страница 2: ...etting up ZB11B 5 5 1 Turn On Turn Off ZB11B 5 5 2 Join the ZigBee Network 6 5 3 Binding 6 5 4 Sleeping Mode 6 5 5 Wake up ZB11B 7 5 6 Battery 7 5 7 Infrared Sensor Detection and Report 7 5 8 Restore to Factory Setting 8 6 Home Automation Clusters for ZB11B 9 7 Important Maintenance Instructions 11 ...

Страница 3: ... ON OFF task to the binding devices according to different report What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is defined for a general purpose cost effective low power consumption low data rate and easy to install wireless solution for ...

Страница 4: ...3 2 Product Appearance Indicator Red Green Binding Key Infrared Sensor Auxiliary Key Sensor Sensitivity Adjuster Release Button Light Sensitivity Adjustor ...

Страница 5: ...non obstacle space Easy installation and configuration 4 Installation A mounting height between 2 and 2 2 meters is recommended Do not aim the passive infrared sensor to a heat or cold source The sensor should not face open door windows as sunlight will affect its operation The sensor must be mounted on a vibration free surface IR coverage range The coverage area A Distance 12 meters sensing angle...

Страница 6: ...B11B Under the circumstances ZB11B is first time used or after resetting when it is powered on and cannot successfully search a network ZB11B will go into turn off mode To manually turn on or turn off ZB11B please use the following instructions ...

Страница 7: ...green 5 times after it is joined successfully Otherwise the indicator will not flash 5 3 Binding To make ZB11B work with another device users need to bind the two devices Step1 Press the Binding Key to broadcast the binding request The indicator will flash green once Step2 The indicator flashes green 5 times after the binding is completed otherwise it flashes green 10 times 5 4 Sleeping Mode ZB11B...

Страница 8: ...n 3 minute 5 7 Infrared Sensor Detection and Report When the infrared sensor detects a movement ZB11B would send the ON task to the binding device based on how bright the location is The light sensitivity can be adjusted by user After ZB11B sends the ON task there will be 2 conditions A No additional movement is detected in 30 seconds it sends the OFF task to the binding device B Further movement ...

Страница 9: ...actory Setting To restore it to factory setting please follow the steps Step1 Press and hold the Auxiliary Key for 10 seconds Step2 Release the button after the indicator shows fast green flashes to complete the restore ...

Страница 10: ...itch 0x0006 Power configurationr 0x0001 Identify 0x0003 Commissioning 0x0015 Poll control 0x0020 Diagnostics Cluster 0x0B05 This lists the attributes of the basic information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only O 0x0002 StackVersion Unsig...

Страница 11: ...string 0 16 bytes Read only O 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x03 M 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0011 PhysicalEnvironmen t 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read write 0x01 M ...

Страница 12: ...tures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the device and damage the device or battery Do not drop knock or shake the device Rough handling would break it Do not use strong chemicals or washing to clean the device Do not paint the device Paint would c...

Страница 13: ...ance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol...

Страница 14: ...13 ...

Отзывы: