11
7. Loading property
Rated Load
(
AC
)
**
Remark**
Max. Load
with LEDs
**Remark**
Max. Inductive
Load
(
cosφ=0.4
)
Max. Load
with Electric
Motors
Max. Surge
Endurable
Surge
Detecion
Overload
Protection
with Auto
Power Cutoff
10A/250V
400W/8
LEDs
for each gang
8A/250V
1.5HP/250V
150A
YES
Yes
This device is not waterproof, after network configuration, place it indoor.
Note
:
1. When measured current is over 10A, the device will cut power within 2 seconds and check if attribute
Bit1(Current OverLoad) level of ACAlarmsMask is 1. If it’s 1 and then device will send Alarm. If it’s 0 and then
device will not send Alarm. When alarm is on, AlarmCluster = 0x0B04, AlarmCode = 0xF0
;
network indicator
flash 10 times (10, 250, 250).
2. Power data saving chip AT2401 : saving data every 30 seconds.
Power data saving chip AT2402 : saving data every 10 seconds.
Power data saving chip:AT2404/08: saving data every second.
3. When device is loaded, it would generate peak power (150A) and device would cut off power in 3 seconds. It
will also send alarm warning, AlarmCluster = 0x0B04
,
AlarmCode = 0xEF
;
network indicator lashes 20 times
(20,250,250).