Introduction 

 

NETVOX Z801WLS is a water or wet Z801WLS. It acts as an end device in the ZigBee 

Home Automation Profile network. It allows

 five Z801WLS types

 to be attached for 

customizing feature. When signal is detected the device sends a warning message to its 

enrolled or bound CIE (a security central) device in the network to notify the user. To know 

more about CIE device please consult your supplier. 

 

What is ZigBee? 

ZigBee  is  a  short  range  wireless  transmission  technology  which  defined  for  a  minimum 

complexity, low power consumption, low data rate, cost effective wireless solution. ZigBee 

lies  in  between  wireless  markup  technology  and  Bluetooth.  ZigBee  is  based  on 

IEEE802.15.4  standard,  the  mutual  co-ordination  between  thousands  of  Z801WLSs  to 

exchange data. Sensor to Z801WLS or node-to-node communication is achieved through 

relays of control data between devices with only a fraction of energy use which denoted 

for highly transmission efficiency. 

 

Note:  Wireless  communication,  in  some  real  use  cases,  can  be  limited  by  the  signal 

blockage. Please consult your service provider or place of purchase. 

 

Product Specification 

 

IEEE 802.15.4 compliant   

 

2.4GHz ISM band (total 16 channels)   

 

3V battery powered 

 

Built-in metal antenna   

 

Transmit up to 80 meters in radius range @ optimum condition   

 

Simple setup and configuration   

 

Содержание ZigBee Z801WLS

Страница 1: ...ZigBeeTM Flood Sensor Flood Sensor User Manual Model Z801WLS FW V3 1 HW V4 3 V4 4...

Страница 2: ...Model Z801WLS Signal 1 Signal 2 Signal 3 Signal 4 Signal 5 Back View Status LED1 Network LED2 GND Binding Key Battery Compartment...

Страница 3: ...ffective wireless solution ZigBee lies in between wireless markup technology and Bluetooth ZigBee is based on IEEE802 15 4 standard the mutual co ordination between thousands of Z801WLSs to exchange d...

Страница 4: ...Operation Step 1 First make sure you have opened up permit join function valid for 60 seconds on a coordinator or a router in the network Step 2 Now power on the Z801WLS device to let it search autom...

Страница 5: ...security Observation If enrollment is successful the status indicator will flash 6 times If CIE device registration table is saturated or failed for other reasons it gives 2 flashes Please apply manua...

Страница 6: ...o factory setting is successful the status indicator light will flash quickly Now the device has restored to the factory setting Now if you wish to join Z801WLS to a new network please power cycle the...

Страница 7: ...e of the 5 S ports 2 Restored the device to factory default setting 3 Then power cycle the device after the device has restored to factory default setting The device regards short circuit is a normal...

Страница 8: ...Netvox related products Z201B Coordinator with CIE Z601A Alarm with Notification...

Страница 9: ...Next Page Device Attributes Description for developers only...

Страница 10: ...IAS Zone 0x0500 None Basic 0x0000 Identify 0x0003 Optional Power configuration 0x0001 None Attributes of the Basic Information Identifie r Name Type Rang e Access Default Mandator y Optional 0x0000 Z...

Страница 11: ...0011 PhysicalEnvironme nt 8 bit Enumeratio n 0x00 0xff Read writ e 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read writ e 0x01 M Attributes of the Power Configuration Information Identifier Name Ty...

Страница 12: ...type 1 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 2 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 3 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 4 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSO...

Страница 13: ...a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and c...

Отзывы: