background image

Clusters of Home Automation for Z801WLS

 

 

Home Automation device feature is defined by the endpoint which contains functional 

clusters. Table 1 lists clusters for the endpoint of Z801WLS

 

 

1)

 

End Point(s)

  0x01

0x02

  0x03

  0x04

  0x05 

2)

 

Device ID

IAS Zone

0x0402

 

3)

 

EndPoint Cluster ID 

Cluster ID for Z801WLS

 

Server side 

Client side 

EP: 0x01 (Device ID: 0x0402 ) 

IAS Zone(0x0500) 

None 

Basic(0x0000) 

 

Identify(0x0003) 

 

Optional

 

Power configuration(0x0001) 

None 

 

Attributes of the Basic Information   

Identifie

Name 

Type 

Rang

Access 

Default 

Mandator

y / 

Optional 

0x0000 

ZCLVersion 

Unsigned 

8-bit 

integer 

0x00 

– 0xff 

Read 

only 

0x03 

0x0001 

ApplicationVersion 

Unsigned 

8-bit 

integer 

0x00 

– 0xff 

Read 

only 

0x1F 

0x0002 

StackVersion 

Unsigned 

8-bit 

integer 

0x00 

– 0xff 

Read 

only 

0x2F 

0x0003 

HWVersion 

Unsigned 

8-bit 

integer 

0x00 

– 0xff 

Read 

only 

0x2B 

0x0004 

ManufacturerNam

Character 

string 

0 – 32 

bytes 

Read 

only 

netvox 

Содержание ZigBee Z801WLS

Страница 1: ...ZigBeeTM Flood Sensor Flood Sensor User Manual Model Z801WLS FW V3 1 HW V4 3 V4 4...

Страница 2: ...Model Z801WLS Signal 1 Signal 2 Signal 3 Signal 4 Signal 5 Back View Status LED1 Network LED2 GND Binding Key Battery Compartment...

Страница 3: ...ffective wireless solution ZigBee lies in between wireless markup technology and Bluetooth ZigBee is based on IEEE802 15 4 standard the mutual co ordination between thousands of Z801WLSs to exchange d...

Страница 4: ...Operation Step 1 First make sure you have opened up permit join function valid for 60 seconds on a coordinator or a router in the network Step 2 Now power on the Z801WLS device to let it search autom...

Страница 5: ...security Observation If enrollment is successful the status indicator will flash 6 times If CIE device registration table is saturated or failed for other reasons it gives 2 flashes Please apply manua...

Страница 6: ...o factory setting is successful the status indicator light will flash quickly Now the device has restored to the factory setting Now if you wish to join Z801WLS to a new network please power cycle the...

Страница 7: ...e of the 5 S ports 2 Restored the device to factory default setting 3 Then power cycle the device after the device has restored to factory default setting The device regards short circuit is a normal...

Страница 8: ...Netvox related products Z201B Coordinator with CIE Z601A Alarm with Notification...

Страница 9: ...Next Page Device Attributes Description for developers only...

Страница 10: ...IAS Zone 0x0500 None Basic 0x0000 Identify 0x0003 Optional Power configuration 0x0001 None Attributes of the Basic Information Identifie r Name Type Rang e Access Default Mandator y Optional 0x0000 Z...

Страница 11: ...0011 PhysicalEnvironme nt 8 bit Enumeratio n 0x00 0xff Read writ e 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read writ e 0x01 M Attributes of the Power Configuration Information Identifier Name Ty...

Страница 12: ...type 1 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 2 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 3 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSOR 0x002A 4 0x04 EMBER_ZCL_IAS_ZONE_TYPE_WATER_SENSO...

Страница 13: ...a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and c...

Отзывы: