background image

ZigBee

TM

- Motion Detector

User Manual

Motion Detector

Model: ZB11A1

20140317
FW V2.0
HW V1.0

Содержание ZB11A1

Страница 1: ...ZigBeeTM Motion Detector User Manual Motion Detector Model ZB11A1 20140317 FW V2 0 HW V1 0...

Страница 2: ...On Turn Off ZB11A1 7 5 2 Join the ZigBee Network 7 5 3 Enroll in the ZigBee Security System 7 5 4 Sleeping Mode 8 5 5 Wake Up ZB11A1 8 5 6 Battery 8 5 7 Infrared Sensor Detection and Report 8 5 8 Tam...

Страница 3: ...urity system When the movement is detected ZB11A1 will notify the central security unit CIE Control and Indicating Equipment device to send commands to a siren device to trigger an alarm What is ZigBe...

Страница 4: ...3 2 Product Appearance Indicator Red Green Binding Key Infrared Sensor Auxiliary Key Sensor Sensitivity Adjuster Release Button...

Страница 5: ...tacle space Easy installation and configuration 4 Installation A mounting height between 2 and 2 2 meters is recommended Do not aim the passive infrared sensor to a heat or cold source The sensor shou...

Страница 6: ...ouble sided tape 1 Clean surface with isopropyl rubbing alcohol wipe gently and let dry 2 Remove one side liner Press adhesive to the bottom of ZB11A1 3 Remove the other side liner Press to surface fo...

Страница 7: ...6...

Страница 8: ...manual of the coordinator or the router to enable the permit join feature Step2 Turn on ZB11A1 It will start to search and join the network Step3 The indicator will flash green once when it finds out...

Страница 9: ...r off the device 5 5 Wake Up ZB11A1 To manually wake up ZB11A1 press the Auxiliary Key once When ZB11A1 is in a ZigBee network it will send out the device data like IEEE address Network address and th...

Страница 10: ...change the detecting sensitivity by adjusting the Sensor Sensitivity Adjuster Clockwise adjustment Higher sensitivity The default sensitivity is medium sensitivity as the picture below 5 8 Tamper Alar...

Страница 11: ...rationr 0x0001 Identify 0x0003 Ias Zone 0x0500 Commissioning 0x0015 None Poll control 0x0020 Diagnostics Cluster 0x0B05 Attributes of the Basic Information Identifier Name Type Range Access Default Ma...

Страница 12: ...ess Default Mandatory Optional string bytes 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x03 M 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0012 DeviceEnabled Boo...

Страница 13: ...ures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the devic...

Страница 14: ...nce with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does caus...

Страница 15: ...14...