Network Joining

 

Never Join the Network 

Turn on the device to search the network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail 

Had joined the network 

(Not in the original setting) 

Turn on the device to search the previous network. 

The green indicator keeps on for 5 seconds: success. 

The green indicator remains off: fail. 

Fail to Join the Network 

Suggest checking the device registration information on the gateway or consulting your 

platform server provider if the device fails to join the network. 

Function Key

 

Press and Hold for 5 Seconds 

Restore to the original setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once 

The device is in the network: the green indicator flashes once and the device sends a data 

report 

The device is not in the network: the green indicator remains off 

Threshold Restore to Factory Setting

 

 

Description 

RA0716 has the function of the power-down saving the memory 

of network-joining information. This function acquiesces in turn off, that is, it will 

rejoin every time when it is power on. If the device is turned on by the 

ResumeNetOnOff command, the last network-joining information will be recorded 

when every time it is power on. (including saving the network address information 

that it is assigned, etc.) If users want to join a new network, the device needs to   

perform the original setting, and it will not rejoin the last network. 

 

Operation Method 

1.

 

Press and hold the binding button for 5 seconds and then release 

(release the binding button when the LED flashes), and the LED flashes 20 times. 

2.

 

The device automatically restarts to rejoin the network. 

 

Low Voltage Threshold

 

Low Voltage Threshold 

10.5 V 

Содержание RA0716

Страница 1: ...opyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be discl...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set up Instruction 3 5 Data Report 5 6 Installation 7 7 Important Maintenance Instruction 8...

Страница 3: ...nsumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communi...

Страница 4: ...Off Power On RA0716 is connected to DC 12V adapter for power on Turn On Connect with power on to turn on Restore to Factory Setting Press and hold the function key for 5 seconds and the green indicat...

Страница 5: ...tor flashes once and the device sends a data report The device is not in the network the green indicator remains off Threshold Restore to Factory Setting Description RA0716 has the function of the pow...

Страница 6: ...interval between two reports must be the MaxTime 3 ReportChange is not supported by RA0716 Invalid configuration The data report is sent according to ReportMaxTime as a cycle the first data report is...

Страница 7: ...value of MaxTime should be 900s 2 Read RA0716 device parameter Downlink 0235000000000000000000 Device Return 8235001E03840000000000 device current parameter Description Device CmdI D DeviceType Netvox...

Страница 8: ...A0716 periodically reports the data including the temperature humidity and PM2 5 according to ReportMaxTime The default MaxTime is 900 seconds Note MaxTime can be modified through the downlink command...

Страница 9: ...batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...