2.

 

Appearance 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

 

Main Feature 

 

2 x 1.5V AAA size alkaline batteries 

 

CO and temperature detection 

 

Compatible with LoRaWAN

TM

 Class A 

 

Frequency hopping spread spectrum 

 

Configuration parameters can be configured via a third-party software platform, data can be read and alerts can be set via SMS 

text and email (optional) 

 

Applicable to the third-party platforms: Actility/ ThingPark, TTN, MyDevices/ Cayenne 

 

Low power consumption and long battery life 

 

Note: Battery life is determined by the sensor reporting frequency and other variables.   

     Please refer to http://www.netvox.com.tw/electric/electric_calc.html.   

  On this website, users can find various types of batteries in different configurations. 

 

Indicator 

Function Key 

Test Key 

Fixed Chassis 

Battery Casing 

 

Содержание RA02C

Страница 1: ...document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in pa...

Страница 2: ...troduction 2 2 Appearance 3 3 Main Feature 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 7 6 Important Mai...

Страница 3: ...tion technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic meter reading buil...

Страница 4: ...s can be set via SMS text and email optional Applicable to the third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is determine...

Страница 5: ...t mode Network Joining Never joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network...

Страница 6: ...t CO alarm bit is 1 If the alarm continues the report will be sent every 30 seconds When the concentration drops below 110ppm the flashing end alarm will be stopped and an alarm will be sent to restor...

Страница 7: ...ice Device Type Report Type NetvoxPayLoadData RA02C 0x11 0x01 Battery 1Byte unit 0 1V CO Alarm 1Byte 0 no alarm 1 alarm HighTempAlarm 1Byte 0 noalarm 1 alarm Reserved 5Bytes fixed 0x00 Example of Upli...

Страница 8: ...ing Min Time 1H 2H 3H Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Description Device CmdID Device Type NetvoxPayLoadData C...

Страница 9: ...t recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no mat...

Страница 10: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: