6
Example of Downlink Data Configuration:
Descriptio
n
Devi
ce
CmdI
D
Device
Type
NetvoxPayLoadData
Off
R816
B01
0x90
0x73
Reserved (9Bytes,Fixed 0x00)
On
0x91
Reserved (9Bytes,Fixed 0x00)
Toggle
0x92
Reserved (9Bytes,Fixed 0x00)
ClearEner
gy
0x93
Reserved (9Bytes,Fixed 0x00)
ReadCurre
ntStatus
0x94
Reserved (9Bytes,Fixed 0x00)
ConfigRe
portReq
0x01
MinTime(2b
ytes Unit:s)
MaxTime(2
bytes
Unit:s)
CurrentChange(2byte
Unit:1mA)
PowerCh
ange
(
2byte
Unit:1W
)
Reserve
d
(1Byte,
Fixed
0x00)
ConfigRe
portRsp
0x81
Status(0x00_
success)
Reserved (8Bytes,Fixed 0x00)
ReadConfi
gReportRe
q
0x02
Reserved (9Bytes,Fixed 0x00)
ReadConfi
gReportRs
p
0x82
MinTime(2bytes
Unit:s)
MaxTime(2b
ytes Unit:s)
CurrentChang
e(2byte
Unit:1mA)
PowerC
hange
(
2byte
Unit:1W
)
Reserve
d
(1Byte,
Fixed
0x00)
The shutdown operation is performed by the downlink control R816B01:
9073000000000000000000
Open operation through the downlink control R816B01:
9173000000000000000000
Toggle operation through the downlink control R816B01:
9273000000000000000000
Clear and reset energy accumulation value operation through the downlink control R816B01:
9373000000000000000000
Set the downlink to report if there is a change within 2 seconds. Report every 5mins if there is no change.
The current change is 100mA, and the power change is 20W:.
01730002012C0064001400
(The device received a success response payload:
8173000000000000000000
)
Operation to read the current report configuration by downlink:
0273000000000000000000
(The device received a success response payload:
82730002012C0064001400
)
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. PowerChange=2W
MaxTime
MaxTime
(MinTime)
(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless PowerChange value.
collects data
REPORTS 50W
collects data
REPORTS 39W
collects data
REPORTS 35W