5
5. Data Report
A version package will be sent immediately after the device is powered on. The device reports data every 15 minutes by default, and the device sends
data by default configuration before any configuration is performed.
Maximum time: 900 seconds
Minimum time: 2 seconds (
Mintime is recommended to set by default 2 seconds. Need to control to reduce frequent Report recommendations by
adjusting reportchange and Max Interval
)
Default reportchange: Current --- 0x64 (100mA)
Power --- 0x14 (20W)
Note: the real data sending cycle is subject to real programming configuration before shipment.
Note: the device reports the switch state first, and after 10 seconds reports the power, current and voltage measurement information status.
Short press the switch or receive the switch command:
The device will be reported immediately.
(Report the switch status first, and after 10 seconds reports the power, current and voltage measurement information status.)
R816B01 default Max Interval = 15min, Min Interval = 2s (if there is a special custom shipping, the configuration is changed according to customer
requirements) The uplink data reported by the device is referenced by the Netvox LoraWAN Application Command document and
http://www.netvox.com.cn:8888/page/index
Data report configuration and sending period are as following:
Example of Uplink Data Report:
1
1
1
Var(Fix=8 Bytes)
Vers
ion
Device
Type
Report
Type
NetvoxPayLoadData
0x0
1
0x73
0x01
OnOff(1Byte,
OFF_0x00,O
N_0x01)
Energy(4B
yte,
unit:1wh)
OverCurrentAlarm
(1Byte
0:noalarm
1:alarm)
DashCurrentAlar
m(1Byte
0:noalarm
1:alarm)
PowerOffAlar
m(1Bytes,
0:noalarm
1:alarm)
0x02
Vol(2Bytes,Unit:1V
)
Current(2Bytes,
Unit:1ma)
Power(2Bytes,U
nit:1W)
Reserved(2Bytes,fixed
0x00)
Uplink example:
0173010000000006000001
The status of the switch is off.
The accumulated value of the energy is 6WH.
The device issues a power off alarm.
0173010000000006010000
The switch status is off.
The accumulated energy value is 6WH.
The device issues an over-current alarm
(the over-current alarm will disconnect the load connected to the R816B01, and the network green light is about 25 times faster)
0173010100000006000000
The status of the switch is ON.
The accumulated energy value is 6WH without any alarm.
01730200DB006400160000
Represents the voltage 219V and the current 100mA, power 20W.
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current
Change≥
Reportable Change
Current Change
<
Reportable
Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval