2. Appearance 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

The other socket type: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Main Characteristic 

 

  100-240VAC 50/60HZ power supply   

 

  Frequency Hopping Spread Spectrum (FHSS) 

 

  LoRaWAN

TM

 Class C compatible   

 

  Configuration parameters can be configured through a third-party software platform 

 

  Available third-party platform: Actility/ThingPark, TTN, MyDevices/Cayenne 

 

  Current, voltage, power and energy detection 

 

  Over-current alarm ,dash current alarm and 

power off alarm

 

 

  A

utomatically disconnect the load when over-current 

 

Factory Restoring Key 

Switch Button 

Network Indicator 

Switch Indicator 

Содержание R809A01

Страница 1: ...e Detection R809A01 User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Characteristic 3 4 Operation 4 5 Data Report 5 6 Load Property 9 7 Product Installation 10 8 Important Maintenance Instruction 11...

Страница 3: ...type R809A01I AU type LoRa Wireless Technology LoRa is a wireless communication technology famous for its long distance transmission and low power consumption Compared with other communication methods...

Страница 4: ...ion parameters can be configured through a third party software platform Available third party platform Actility ThingPark TTN MyDevices Cayenne Current voltage power and energy detection Over current...

Страница 5: ...mation on the gateway or consult your platform server provider Function Key Restore to factory setting Press and hold the factory restoring key for 5 seconds to restore to factory setting The green in...

Страница 6: ...s data in the default configuration before any configuration is done Default setting MaxTime Max Interval 900s 15 min MinTime Min Interval 2 s Current Change 0x0064 100mA Power Change 0x14 20W Note 1...

Страница 7: ...alarm 1 alarm DashCurrentAlarm 1Byte 0 noalarm 1 alarm PowerOffAlarm 1Bytes 0 noalarm 1 alarm 0x02 Vol 2Bytes Unit 1V Current 2Bytes Unit 1ma Power 2Bytes Unit 1W Reserved 2Bytes fixed 0x00 Uplink exa...

Страница 8: ...eportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s CurrentChange 2b...

Страница 9: ...If the data change is not greater than the last reported data the device will report based on the MaxTime interval 2 For the energy consumption detection device because the device is a constant power...

Страница 10: ...6 Load Property When the detected current exceeds the rated load current range the device will automatically disconnect the load within 2 seconds after the detection Rated Load AC Max Load Max Induct...

Страница 11: ...imited to the following Family School Hospital Shopping mall When electrical equipment needs turn on off regularly remote and scene control The Wireless Power Outlet R809A01 is a removable plug and pl...

Страница 12: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...

Отзывы: