background image

 

 

4. Set up Instruction 

On/Off 

 

Power On 

Connect to battery pack 

Turn On 

Connect the battery pack directly to boot 

Turn Off (Restore to factory setting)  Press and hold the function key for 5 seconds and the green indicator flashes 20 times. 

Power Off 

Remove battery pack 

Network Joining 

 

Never Join the Network 

Turn on the device to search the network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

Turn on the device to search the previous network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Fail to join the network 

Suggest to check the device verification information on the gateway or consult your platform 

server provider. 

Function Key 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once 

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

Sleeping Mode 

 

The device turns on and joins in the 

network 

Sleeping period: Min Interval 

When the reportchange exceeds setting value or the state changes, send a data report 

according to Min Interval 

Low Voltage Threshold Alarm 

 

Low Voltage 

6.8 V 

 

 

 

 

Содержание R72632A01

Страница 1: ...ology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Страница 2: ...Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 6 Installation 7 7 Information about Battery Passivation 8 7 1 To determine whether a battery requires activa...

Страница 3: ...letely waterproof which greatly facilitates the customer s systematic evaluation of soil conditions LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and...

Страница 4: ...can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayen...

Страница 5: ...seconds success The green indicator remains off fail Fail to join the network Suggest to check the device verification information on the gateway or consult your platform server provider Function Key...

Страница 6: ...The data transmission cycle of the device is subject to the burning configuration and there is no minimum time The value of ReportMaxTime should be greater than or equal to 60 seconds 3 In order to m...

Страница 7: ...2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData CmdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes Example o...

Страница 8: ...ltiple times to obtain the average value within a small range of a measurement point 2 Buried measurement method Dig a pit with a diameter of 20cm vertically insert the sensor steel needle horizontall...

Страница 9: ...vents rapid self discharge caused by continuous reaction between lithium and thionyl chloride but battery passivation may also lead to voltage delay when the batteries are put into operation and our d...

Страница 10: ...e Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Treating equipment roughly can destroy intern...

Отзывы: