2.

 

 Appearance 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Main Features 

 

 

Apply SX1276 wireless communication module 

 

2 ER34615 lithium batteries, total battery capacity is 19000mAh 

 

Detect the content of nitrogen, phosphorus and potassium in soil 

 

Protection Class: Main body-IP65, NPK Sensor IP68 

 

Compatible with LoRaWAN

TM

 Class A 

 

Frequency hopping spread spectrum 

 

Configuration parameters can be configured via a third-party software platform, data can be read and alerts can be set via SMS 

text and email (optional) 

 

Applicable to third-party platforms: Actility / ThingPark, TTN, MyDevices/Cayenne 

 

Low power consumption and long battery life 

Note:  

Battery life is determined by the sensor reporting frequency and other variables, 

please refer to 

http://www.netvox.com.tw/electric/electric_calc.html

 

On this website, users can find battery lifetime for varied models at different configurations. 

Indicator 

Function Key 

NPK Sensor 

Battery pack 

Содержание R72632A

Страница 1: ...ogy Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties i...

Страница 2: ...ontent 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 6 Installation 7 7 Important Maintenance In...

Страница 3: ...ely waterproof which greatly facilitates the customer s systematic evaluation of soil conditions LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and low...

Страница 4: ...can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayen...

Страница 5: ...ice verification information on the gateway or consult your platform server provider Function Key Press and hold for 5 seconds Restore to factory setting Turn off The green indicator flashes 20 times...

Страница 6: ...he data transmission cycle of the device is subject to the burning configuration and there is no minimum time The value of ReportMaxTime should be greater than or equal to 60 seconds 3 In order to mak...

Страница 7: ...2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData CmdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes Example o...

Страница 8: ...ltiple times to obtain the average value within a small range of a measurement point 2 Buried measurement method Dig a pit with a diameter of 20cm vertically insert the sensor steel needle horizontall...

Страница 9: ...r assembly will be affected 7 Important Maintenance Instruction The device is a product with superior design and craftsmanship and should be used with care The following suggestions will help you use...

Отзывы: