background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function Key

 

Press and Hold for 5 Seconds 

Restore to the original setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once 

The device is in the network: the green indicator flashes once and the device sends a data 

report 

The device is not in the network: the green indicator remains off 

Low Voltage Threshold

 

Low Voltage Threshold 

6.8 V 

Threshold Restore to Factory Setting

 

 

Description 

R72616A has the function of the power-down saving the memory 

of network-joining information. This function acquiesces in turn off, that is, it will 

rejoin every time when it is power on. If the device is turned on by the 

ResumeNetOnOff command, the last network-joining information will be recorded 

when every time it is power on. (including saving the network address information 

that it is assigned, etc.) If users want to join a new network, the device needs to   

perform the original setting, and it will not rejoin the last network. 

 

Operation Method 

1.

 

Press and hold the binding button for 5 seconds and then release 

(release the binding button when the LED flashes), and the LED flashes 20 times. 

2.

 

The device automatically restarts to rejoin the network. 

 

Содержание R72616A

Страница 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other p...

Страница 2: ...able of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 4 4 Set up Instruction 4 5 Data Report 6 6 Installation 8 7 Information about Battery Passivation 10 8 Important Maintenance Instruction...

Страница 3: ...ompared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For...

Страница 4: ...3 Battery Pack 2 Appearance Temperature and Humidity Sensor PM2 5 Sensor Indicator Function Key DC in Batteries ER14505x8 pcs...

Страница 5: ...Connect to the battery pack to turn on directly Restore to Factory Setting Press and hold the function key for 5 seconds and the green indicator flashes 20 times Power Off Remove the batteries Note 1...

Страница 6: ...he memory of network joining information This function acquiesces in turn off that is it will rejoin every time when it is power on If the device is turned on by the ResumeNetOnOff command the last ne...

Страница 7: ...supported by R72616A Invalid configuration The data report is sent according to ReportMaxTime as a cycle The first data report is the start to the end of a cycle 4 Data pocket PM2 5 temperature and h...

Страница 8: ...nt 1 3 The MinTime setting of EU868 cannot be less than 120s and the MaxTime cannot be less than 370s 2 Read R72616A device parameter Downlink 026A000000000000000000 Device Return 826A001E0E1000000000...

Страница 9: ...nsert 8 ER14505 3 6V batteries into the battery compartment 4 sections on the front and 4 sections on the back side After loading the battery install the battery PCB board face up and attach it to the...

Страница 10: ...When the ambient sensor temperature and humidity _PM2 5 R72616A regularly reports data according to Max Time temperature humidity and PM2 5 concentration value the default Max Time are 180 seconds Not...

Страница 11: ...tery passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from...

Страница 12: ...batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board...

Отзывы: