7
Example of ReportDataCmd
FPort
:
0x06
Bytes
1
1
1
Var(Fix=8 Bytes)
Version
DeviceType
ReportType
NetvoxPayLoadData
Version
– 1 byte –0x01
——
the Version of NetvoxLoRaWAN Application Command Version
DeviceType
– 1 byte – Device Type of Device
The devicetype is listed in Netvox LoRaWAN Application Devicetype doc
ReportType
– 1 byte –the presentation of the NetvoxPayLoadData
,
according the devicetype
NetvoxPayLoadData
– Fixed bytes (Fixed =8bytes)
Device
Device
Type
Report
Type
NetvoxPayLoadData
RA07 Series
R726 Series
RA07xxY Series
0x05
0x09
0x0D
0x05
Battery
(1Byte, unit:0.1V)
O3
(2Byte ,0.1ppm)
CO
(2Byte ,0.1ppm)
NO
(2Byte ,0.1ppm)
Reserved
(1Bytes,fixed 0x00)
Uplink 1: 01050500FFFF0064FFFF00 (RA0701)
1
st
byte (01): Version
2
nd
byte (05): DeviceType 0x05
-
RA07 Series
3
rd
byte (05): ReportType
4
th
byte (00): DC power supply
5
th
6
th
byte (FFFF): O3
7
th
8
th
byte (0064): CO
-
10ppm , 64 H
ex
=100 D
ec
100*0.01=10 ppm
9
th
10
th
byte (FFFF): NO
11
th
byte (00): Reserved
Uplink 2: 01090578FFFF0064FFFF00 (R72601)
1
st
byte (01): Version
2
nd
byte (09): DeviceType 0x09
-
R726 Series
3
rd
byte (05): ReportType
4
th
byte (78): Battery
-
12v , 78 H
ex
=120 D
ec
120*0.1v=12v
5
th
6
th
byte (FFFF): O3
7
th
8
th
byte(0064): CO
-
10ppm , 64 H
ex
=100 D
ec
100*0.01=10 ppm
9
th
10
th
byte (FFFF): NO
11
th
byte (00): Reserved