7
5. Data Report
Hand Wash Detection:
After power on, the device will immediately send a version packet report and a data report including the voltage of the
battery and the current state of the hand wash.
Water Leakage Detection:
After power on, the device will immediately send a version packet report and a data report including the voltage of the
battery and the current state of the water leakage.
The device sends data according to the default configuration before any other configuring.
Default setting:
Report MaxTime
:
Max Interval =3600s (1 hour)
Report MinTime
:
Min Interval =3600s (1 hour) (Every Min Interval will detect the current voltage one time)
Reportchange
:
BatteryChange : 0x01(0.1v)
* If there is a special customized order, the setting of the device will change according to customer’s requirements
R720F trigger:
1.
It can be used to detect the current voltage and the current state of hand wash according to the default.
2.
As soon as the device detects the change in the current state of the hand wash, it will report a data packet including the
current voltage value and the current state of the hand wash.
3.
Press the button, and it will immediately detect the current voltage and the current state of the hand wash, and then report
a currently detected data packet.
Note:
1. The cycle of the device sending the data report is according to the default.
2. The interval between two reports must be the MinTime.
The device reported data parsing please refer to Netvox LoRaWAN Application Command document and Netvox Lora
Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
Data report configuration and sending period are as following:
Min Interval
(Unit: second)
Max Interval
(Unit: second)
Reportable Change
Current Change
≥
Reportable Change
Current Change<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0
Report
per Min Interval
Report
per Max Interval