6
4.Set up Instruction
On/Off
Power On
Insert batteries. (users may need a screwdriver to open)
Turn On
Press and hold the function key for 3 seconds till the green indicator flashes once.
Turn Off (Restore to factory setting) Press and hold the function key for 5 seconds and the green indicator flashes 20 times.
Power Off
Remove Batteries
Note
1. Remove and insert the battery: the device is in the turn-off state by default.
2. After 5 seconds of powering on, the device is in engineering testing mode.
3. Every time, after remove and reinsert the battery, the device is in a turn-off state and
need to turn on again.
4. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components.
Network Joining
Never Join the Network
Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Fail to join the network
Suggest to check the device verification information on the gateway or consult your platform
server provider.
Function Key
Press and hold for 5 seconds
Restore to factory setting / Turn off
The green indicator flashes 20 times: success
The green indicator remains off: fail
Press once
The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off
Sleeping Mode
The device turns on and joins in the
network
Sleeping period: Min Interval
When the reportchange exceeds setting value or the state changes, send a data report
according to Min Interval
Low Voltage Threshold Alarm
Low Voltage
3.2 V