background image

 

 

4.Set up Instruction 

On/Off 

 

 

Power On 

Insert batteries. (users may need a screwdriver to open) 

 

Turn On 

Press and hold the function key for 3 seconds till the green indicator flashes once. 

 

Turn Off (Restore to factory setting)  Press and hold the function key for 5 seconds and the green indicator flashes 20 times. 

 

Power Off 

Remove Batteries 

 

Note 

1.  Remove and insert the battery: the device is in the turn-off state by default. 

2.  After 5 seconds of powering on, the device is in engineering testing mode. 

3.  Every time, after remove and reinsert the battery, the device is in a turn-off state and  

   need to turn on again. 

4.  On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor  

   inductance and other energy storage components. 

 

Network Joining 

 

 

Never Join the Network 

Turn on the device to search the network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

 

Had joined the network 

Turn on the device to search the previous network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

 

Fail to join the network 

Suggest to check the device verification information on the gateway or consult your platform 

server provider. 

 

Function Key 

 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

 

Press once 

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

 

Sleeping Mode 

 

 

The device turns on and joins in the 

network 

Sleeping period: Min Interval 

When the reportchange exceeds setting value or the state changes, send a data report 

according to Min Interval 

 

Low Voltage Threshold Alarm 

 

 

Low Voltage 

3.2 V 

 

Содержание R720F

Страница 1: ...720F Series User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ...able of Content 1 Introduction 2 2 Appearance 3 3 Main Features 5 4 Set up Instruction 6 5 Data Report 7 6 Installation 11 7 Information about Battery Passivation 12 8 Important Maintenance Instruction 13 ...

Страница 3: ...and wash and a currently detected data packet will be reported Water Leakage Detection 1 Regularly check the current voltage and state of water leakage according to the configured time 2 When the device detects the change in the current water leakage state it will report a data packet with the current voltage and state of water leakage 3 Press the function key to immediately detect the current vol...

Страница 4: ...3 2 Appearance Hand Wash Detection R720FLO L type Probe Electrode rods Upward R720FLD L type Probe Electrode rods Downward Function Key Indicator Electrode Rod ...

Страница 5: ...4 R718FU U type Probe Water Leakage Detection R720W ...

Страница 6: ...s can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is determined by the sensor reporting frequency and other variables please refer to http www netvox com tw electric electric_calc html...

Страница 7: ...work Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the network Suggest to check the device verification information on the gateway or consult y...

Страница 8: ...urrent voltage and the current state of hand wash according to the default 2 As soon as the device detects the change in the current state of the hand wash it will report a data packet including the current voltage value and the current state of the hand wash 3 Press the button and it will immediately detect the current voltage and the current state of the hand wash and then report a currently det...

Страница 9: ...figReport Rsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 1 Configure R720F device parameter MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 01B7003C003C0100000000 Device return 81B7000000000000000000 confi...

Страница 10: ...is 1 meaning it has hand wash Uplink 01B7012400000000000000 The report of the status is 0 meaning it has no hand wash Water Leakage Detection Uplink 01B7012401000000000000 The report of the status is 1 meaning it has water leakage Uplink 01B7012400000000000000 The report of the status is 0 meaning it has no water leakage Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1...

Страница 11: ...alue too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects...

Страница 12: ...d according to personal requirements 3 When the level of the hand wash is lower than electrode rods the device will issue a warning R720FLD R720FLO R720FU L type Probe Electrode rods Downward L type Probe Electrode rods Upward U type Probe Installation method of water leakage detection device Place the device on the location where water leakage needs to be detected If users need to detect water le...

Страница 13: ...f they are in storage for a long time or if the storage temperature is too high This lithium chloride layer prevents rapid self discharge caused by continuous reaction between lithium and thionyl chloride but battery passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source ba...

Страница 14: ...y batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Treating equipment roughly can destroy internal circuit boards and delicate structures Do not wash with strong chemicals detergents or strong detergents Do not ...

Отзывы: