8
Set Report Time
(1)
Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v,
DistanceChange = 500mm
、
TemperatureChange=2°C
Downlink: 0134003C003C0101F40014 003C(H
ex)
= 60(D
ec),
01F4(H
ex)
= 500(D
ec),
14(H
ex)
= 20(D
ec)
Device returns:
8134000000000000000000 (Configuration is successful)
8134010000000000000000 (Configuration failed)
(2)
Read device parameters
Downlink: 0234000000000000000000
Device returns:
8234003C003C0101F40014 (current device parameters)
Set Total Height of The Container
(3)
Setting the total height of the container, FillMaxDistance = 5000mm
Downlink: 0534138800000000000000 1388(H
ex)
= 5000(D
ec),
Device returns:
8534000000000000000000 (Configuration is successful)
8534010000000000000000 (Configuration failed)
(4)
Read the total height of the container (FillMaxDistance)
Downlink:0634000000000000000000
Device returns:
8634138800000000000000 (Device current parameter)
Switch the Mode
If the mode of the device is waste bin detection, switch it to parking detection.
(5)
Set FillMaxDistance to 0
Downlink
:
0534000000000000000000
Device returns
:
8534000000000000000000
(6)
Read FillMaxDistance, and check whether it is set successfully.
Downlink
:
0634000000000000000000
Device returns
:
8634000000000000000000