6. Installation 

When using it, the back of it can be adsorbed on the iron surface, or the two ends can be fixed to the wall with screws. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 
 
 
 
 

 
 

 
 
 

 

 

 

 

 

 

 

 

 

 

1.The Wireless Water Leak Detector/Temperature/Humidity Sensor   

(R718WAA) has a built-in magnet (as Figure 1 below). 

It can be attached to the surface with iron material during 

installation. 

To make the installation more secure, please use screws 

(purchased separately) to fix the device on the wall or other 

objects 

Note: 

Do not install the device in a metal shielded box or in an 

environment surrounded by other electrical equipment to avoid 

affecting the wireless transmission of the device. 

 

3. When the sensor probe detects the leak, the device 

will send an "alarm" message. 

After remove the probe from the accumulated leakage 

and drain the remaining water from the sensor, the 

device will restore to the "normal" state and send the 

"normal" status message. 

 

2. Remove the 3M release paper (as the red part of the 

above figure) on the back of the sensor probe and 

attach it to the smooth ground that may accumulate 

leakage (as the right figure). 

 

The R718WAA can be used in the following scenarios: 

 

Data centers and rooms. 

 

File storage center. 

 

Basement leakage detection 

 

Water pipe leakage detection 

 

The bottom of the cabin detection

 

This

 

device is designed to detect water leakage and is not suitable 

for detecting hazardous chemical, solvent, oil, fuel, strong acid or 

other corrosive liquid. 

Note: 

Please do not disassemble the device unless it is required to replace the batteries. Do not touch the waterproof gasket, LED 

indicator light, function keys when replacing the batteries. Please use suitable screwdriver to tighten the screws (if using an electric 

screwdriver, it is recommended to set the torque as 4kgf) to ensure the device is impermeable.

 

Содержание R718WAA

Страница 1: ...ight Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed...

Страница 2: ...eport 5 5 1 Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 7 5 3 Example for MinTime MaxTime logic 7 6 Installation 9 7 Information about Battery Passivation 10 7 1 To determine whether a batt...

Страница 3: ...y LoRa is a wireless communication technology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to...

Страница 4: ...configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Impr...

Страница 5: ...Had joined the network not at factory setting Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Failed t...

Страница 6: ...0s if there is special customized shipment the setting will change according to the customer s requirements MinTime 3600s by default the current voltage value is detected every min interval Battery Ch...

Страница 7: ...yte 0B Hardware Version V1 1 6th 9th byte 20200520 DateCode 2020 05 20 10th 11th byte 0000 Reserved Uplink 2 01BE012406701A9E010000 Status report 1st byte 01 Version 2nd byte BE DeviceType 0xBE R718WA...

Страница 8: ...02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s Battery Change 1byte Unit 0 1v Temperature Change 2byte Unit 0 01 HumidityChange 2byte Unit 0 01 1 C...

Страница 9: ...xTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the dev...

Страница 10: ...ater from the sensor the device will restore to the normal state and send the normal status message 2 Remove the 3M release paper as the red part of the above figure on the back of the sensor probe an...

Страница 11: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: