
5
5. Data Report
When the device is powered on, it will immediately send a version package report and then report the device data.
Default setting:
Min interval = 10s (subject to factory setting)
Max interval = 15min (subject to factory setting)
R718UBB,R718UBB1,R718UBB12 reportcount=1
R718UBB123,R718UBB23,R718UBB25,R718UBB125,R718UBB235,R718UBB1235 reportcount=2
Data detection:
When the device is in a network state, the light flashes once after pressing the key, and then reads the data. When the time to
return the corresponding data or configure is up, it will also detect and return the corresponding data information.
(Note: The interval between multiple data packets is mintime)
Note:
1. Before any configuration, the device sends data according to the default configuration.
2. Do not send any configuration before turn on the device.
3.
CO2 data will be unstable due to transportation relations, long storage time and other factors.
If the CO2 value which customers test is inconsistent ,or there is large discrepancy of the primary standard,
it can be recalibrated. For specific calibration methods,please refer to command 0x03 CalibrateType.
Refer to Netvox LoRaWan Application Command documents and for data analysis reported by the device
http://www.netvox.com.cn:8888/page/index
The report configuration and sending time are as follows:
Min Interval (Unit: s)
Max Interval (Unit: s)
Not 0
Mintime * reportcount ~ 65535