11
Brand
Load Resistance
Activation Time
Activation Current
NHTONE
165 Ω
5 minutes
20mA
RAMWAY
67 Ω
8 minutes
50mA
EVE
67 Ω
8 minutes
50mA
SAFT
67 Ω
8 minutes
50mA
Note:
If you buy batteries from other than the above four manufacturers, then the battery activation time, activation current, and required
load resistance shall be mainly subject to the announcement of each manufacturer.
7. Precautions for Outdoor Installation
According to Enclosure Protection Class
This standard is equivalent to IEC 60529:2001 Degrees of Protection Provided by Enclosures
The test method of IP65 waterproof grade is:
spray the device in all directions under 12.5L/min water flow for 3min, and the internal electronic function is normal.
The test method of IP67 waterproof grade is:
the device is immersed in 1m deep water for 30min, and the internal electronic function is normal.
IP65, dust-proof and to prevent damage caused by water from nozzles in all directions from invading electrical appliances. It can be
used in general indoor environment and sheltered outdoor environment.
It is not suitable for use in environments with high water pressure, high temperature and high humidity, such as long time direct sunlight
outdoors and possible direct exposure to rainstorm.
If it is really necessary to install in harsh environments, it is recommended to add
sunscreen and rainproof shields when installing.
Case I (face down with LED and buttons)
Case II (installed under the rain shield)