4. Operation 

 

On/Off 
 

 

Power on 

Insert batteries. (users may need a flat blade screwdriver to open) 

Turn on   

Press and hold the function key for 3 seconds till the green indicator flashes once.   

Turn off 
(Restore to factory setting) 

Press and hold the function key for 5 seconds till the green indicator flashes for 20 times. 

Power off 

Remove batteries 

Note: 

1. At 1

st

-5th second after power on, the device will be in engineering test mode.   

2. Remove and insert the battery; the device is at off state by default. Turn on the device to use again.   
3. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other     

energy storage components. 

 
Network Joining 
 

 

Never joined the network 
 

Turn on the device to search the network to join. 
The green indicator stays on for 5 seconds: success 
The green indicator remains off: fail 

Had joined the network 
(not at factory setting.) 

Turn on the device to search the previous network to join. 
The green indicator stays on for 5 seconds: success 
The green indicator remains off: fail 

Fail to join the network   
(when the device is on) 

First two mins: wake up every 15 seconds to send request. 
After two mins: enter sleeping mode and wake up every 15 minutes to send request. 
Note: Suggest to remove batteries if the device is not used to save power.   
     Suggest to check the device verification information on the gateway or consult your platform server provider. 

 
Function Key 
 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 
The green indicator flashes for 20 times: success 
The green indicator remains off: fail 

Press once   

The device is in the network: The green indicator flashes once and sends a data report 
The device is not in the network: the green indicator remains off 

 
Sleeping Mode 

 

The device is on and in the 
network 

Sleeping period: Min Interval. 
When the reportchange exceeds setting value or the state changes: send a data report according to Min Interval.   

The device is on but not in   
the network 

First two mins: wake up every 15 seconds to send request. 
After two mins: enter sleeping mode and wake up every 15 minutes to send request. 
Note: Suggest to remove batteries if the device is not used.   
     Suggest to check device verification on gateway. 

 

Low Voltage Warning 
 

Low Voltage 

3.2V 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание R718PB15

Страница 1: ...ual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 2 3 Main Characteristics 2 4 Operation 3 5 Data Report 4 6 Installation 5 7 Important Maintenance Instruction 6...

Страница 3: ...ses LoRa technology to define end to end standard specifications to ensure interoperability between devices and gateways from different manufacturers 2 Appearance 3 Main Characteristics Using SX1276 w...

Страница 4: ...r remains off fail Fail to join the network when the device is on First two mins wake up every 15 seconds to send request After two mins enter sleeping mode and wake up every 15 minutes to send reques...

Страница 5: ...sample and process the collected value if you were to manually trigger the device by pressing the button please be patient Data report configuration and sending period are as following 1 Configure de...

Страница 6: ...soil at the bottom of the hole Many people have used a simple piece of PVC pipe with a notch cut in the end for the sensor to sit in with the sensor cable routed inside the pipe 3 After inserting the...

Страница 7: ...stroy batteries and deform or melt some plastic parts Do not store in a cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do...

Отзывы: