5
5. Data Report
The device will immediately send a version package report. Then, it will send a report data with
the noise value
after it is powered on for 20s
.
The device sends data according to the default configuration before any other configuration.
Default setting:
MaxTime: Max Interval = 3min = 180s
MinTime: The MinTime configuration is not available.
*But the software has restriction, MinTime must be configured a number greater than 0.
Note:
1.
The cycle of the device sending the data report is according to the default.
2.
R718PA7 reports the noise value.
The data parsing reported by the device is referenced by the Netvox LoraWAN Application Command
document and http://www.netvox.com.cn:8888/page/index
Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var (Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)