background image

 

 

1.

 

Introduction 

 

 

The R718MBC series equipment is a vibration alarm device for Netvox ClassA type equipment based on the LoRaWAN open 

protocol. It can count time of the movement or vibration duration of the equipment and is compatible with the LoRaWAN 

protocol. 

 

LoRa Wireless Technology: 

LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other 

communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance. 

Widely used in long-distance, low-data wireless communications. For example, automatic meter reading, building automation 

equipment, wireless security systems, industrial monitoring. Main features include small size, low power consumption, 

transmission distance, anti-interference ability and so on. 

 

LoRaWAN: 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and 

gateways from different manufacturers.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание R718MBC

Страница 1: ...This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or...

Страница 2: ...Report Data 6 5 2 Example of Config Report Time 7 5 3 Example of Config R718MBType 7 5 4 Example of Config Active Threshold 8 6 Information about Battery Passivation 9 6 1 To determine whether a batt...

Страница 3: ...red with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For exa...

Страница 4: ...g spread spectrum Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platfo...

Страница 5: ...k Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the dev...

Страница 6: ...fter entering the stationary state for 5 seconds sends a report of the vibration duration and restarts a new round of detection and the timing is cleared If vibration continues to occur during this pr...

Страница 7: ...y 1Byte unit 0 1V Workdurationtime 4Bytes unit 1s Reserved 3Bytes fixed 0x00 Example 1 of Uplink 012C012400000018000000 1st byte 01 Version 2nd byte 2C DeviceType R718MBC 3rd byte 01 ReportType 4th by...

Страница 8: ...ed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 1 Configure device parameters MinTime 5 min MaxTime 5min Battery...

Страница 9: ...000000 Current device type is R718MBA 5 4 Example of Config Active Threshold FPort 0x07 Description Device Cmd ID Device Type NetvoxPayLoadData SetActive ThresholdReq R718MBC 0x05 0x2C Threshold 2Byte...

Страница 10: ...nd our devices may not work correctly in this situation As a result please make sure to source batteries from reliable vendors and it is suggested that if the storage period is more than one month fro...

Страница 11: ...rature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and del...