background image

                                                                                                                      Model

R718MA   

 

 

 

 

Wireless Asset Sensor

 

 
 

 

 

 

 

Wireless Asset Sensor

 

R718MA   

User Manual 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

Содержание R718MA

Страница 1: ...Model R718MA Wireless Asset Sensor Wireless Asset Sensor R718MA User Manual ...

Страница 2: ...Features 3 4 Set up Instruction 3 4 1 Power on and Turn on off 3 4 2 Join Into LoRa Network 4 4 3 Function Key 4 4 4 Data Report 5 5 Restore to Factory Setting 5 6 Sleeping Mode 7 7 Low Voltage Alarming 7 8 Installation 7 9 Important Maintenance Instruction 8 ...

Страница 3: ...echnology LoRa is a wireless communication technology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems ind...

Страница 4: ...o sections of 3 6V ER14505 AA batteries and close the battery cover 2 Turn on if the device had never joined in any network or at factory setting mode after powering on the device is at off mode by default setting Press and hold function key for 3 seconds till the green indicator flashes once and release to turn on device 3 Turn off Press and hold function key for 5 seconds till the green indicato...

Страница 5: ...with LoRa gateway The network operation is as following 1 If the device had never joined any network turn on the device it will search an available LoRa network to join The green indicator will stay on for 5 seconds to show it joins into the network otherwise the green indicator will be off 2 If R718MA had been joined into a LoRa network remove and insert the batteries it will repeat step 1 4 3 Fu...

Страница 6: ... based on MinTime 15 Minutes MaxTime 1 Hour battery voltage Reportable Change 0 1V MaxTime Sleeping MinTime sleeping sleeping sleeping 0H 15 th M 30 th M 45 th M 1H 2H REPORT 100mV Min Interval Unit second Max Interval Unit second Reportable Change Current Change Reportable Change Current Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Int...

Страница 7: ...alue too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started Wakes up and collects data REPORTS 3 6 Wakes up and collects data 3 6 3 6 3 6 0 0 1 Does not report Wakes up and coll...

Страница 8: ...rtchange is larger than setting value it will wake up and send a data report B When it is not in the network R718MA will enter sleeping mode and wake up every 15 seconds to search a network to join in the first two minutes After two minutes it will wake up every 15 minutes to request to join the network If it s at B status to prevent this unwanted power consumption we recommend that users remove t...

Страница 9: ...estroy batteries and deform or melt some plastic parts Do not store in a cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not wash with strong chemicals detergents or strong detergents Do not ap...

Отзывы: