4.

 

Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a screwdriver to open) 

Turn on   

Press and hold the function key for 3 seconds till the green indicator flashes 

once.   

Turn off   

(Restore to factory setting) 

Press and hold the function key for 5 seconds till green indicator flashes for 

20 times. 

Power off 

Remove Batteries.   

Note 

1.

 

Remove and insert the battery; the device is at off state by default. 

2.

 

On/off interval is suggested to be about 10 seconds to avoid the 

interference of   

capacitor inductance and other energy storage components. 

3. At 1

st

 -5

th

 second after power on, the device will be in engineering test 

mode.   

Network Joining 

 

Never joined the network 

Turn on the device to search the network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

(not at factory setting) 

Turn on the device to search the previous network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Function Key 

 

Press and hold for 5 

seconds 

Restore to factory setting / Turn off 

The green indicator flashes for 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

 

 

 

Содержание R718LB2

Страница 1: ...ight Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed...

Страница 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 10 7 Information about Battery Passivation 13 7 1 To determine whether a battery requires activation 13 7 2 How to activate the...

Страница 3: ...n methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For...

Страница 4: ...Compatible with LoRaWANTM Class A Using frequency hopping spread spectrum technology Configurable parameters via third party software platform reading data and setting alarms via SMS text and email o...

Страница 5: ...1st 5th second after power on the device will be in engineering test mode Network Joining Never joined the network Turn on the device to search the network to join The green indicator stays on for 5 s...

Страница 6: ...he magnet removes the Hall sensor it will report the status 1 The distance between the magnet and the Hall sensor is greater than 3 cm Note The device report interval will be programmed based on the d...

Страница 7: ...table Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq...

Страница 8: ...sponse 8245003C003C0100000000 Current configuration Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime S...

Страница 9: ...it is sleeping it does not collect data Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data REPORT 3 6V Wakes up and collects dat...

Страница 10: ...er than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up f...

Страница 11: ...th iron material during installation To make the installation more secure please use screws purchased separately to fix the device on the wall or other objects see Figure 2 below Comment Do not instal...

Страница 12: ...nsor The Wireless 2 gang Hall Type Open Close Detection Sensor R718LB2 can be used in the following scenarios Door window Machine room door Archives Closet Refrigerators and freezers Cargo ship door G...

Страница 13: ...12 If the magnet moves along the Y axis relative to the sensor it will cause repeated reports due to the magnetic field...

Страница 14: ...passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from rel...

Страница 15: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: