1. Introduction   

The R313M is a door bell button device for Netvox ClassA type devices based on the LoRaWAN 

open protocol and is compatible with the LoRaWAN protocol. 

 

LoRa Wireless Technology: 

LoRa is a wireless communication technology dedicated to long distance and low power 

consumption. Compared with other communication methods, LoRa spread spectrum modulation 

method greatly increases to expand the communication distance. Widely used in long-distance, 

low-data wireless communications. For example, automatic meter reading, building automation 

equipment, wireless security systems, industrial monitoring. Main features include small size, low 

power consumption, transmission distance, anti-interference ability and so on. 

 

LoRaWAN: 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure 

interoperability between devices and gateways from different manufacturers.   

2.

 

Appearance 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Indicator 

Door Bell Button   

Function Key 

Содержание R313M

Страница 1: ...s document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 6 6 Installation 11 7 Important Maintenance Instruction 12...

Страница 3: ...od greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless secur...

Страница 4: ...atform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery...

Страница 5: ...e by default 2 On off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other energy storage components 3 If press any function key and insert batterie...

Страница 6: ...and sends a report The device is not in the network green indicator remains off Press doorbell button Trigger the doorbell alarm Note Users can configure the button pressing time to send alarm by com...

Страница 7: ...th an uplink packet including door bell alarm The device sends data in the default configuration before any configuration is done Default setting Maximum time 3600s Minimum time 3600s Battery change 0...

Страница 8: ...000000 Configuration failure 2 Read Configuration Downlink 0255000000000000000000 Response 8255003C003C0100000000 Current configuration Description Device Cmd ID Device Type NetvoxPayLoadData Config R...

Страница 9: ...iguration Description CmdID PayLoad Fix byte 1byte SetButtonPressTimeReq 0x01 PressTime 1bytes 0x00_QuickPush_Less then 1 Second 0x01_1 Second push 0x02_2 Seconds push 0x03_3 Seconds push 0x04_4 Secon...

Страница 10: ...based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping sleeping 0H 15th M 30th M 45th M 1H 2H Wakes up and collects data...

Страница 11: ...e reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be draine...

Страница 12: ...smooth wall please do not stick it to the rough wall to avoid falling off after a long time use Note Wipe the wall surface before installation to avoid dust on the wall surface and affect the paste c...

Страница 13: ...the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boar...

Отзывы: