5
Sleeping Mode
The device is turn on and join in the
network
Sleeping period: Min Interval.
When the reportchange exceeds the default or the state of the device changes: send a data
report according to Min Interval.
Low Voltage Warning
Low Voltage
2.4V
5. Data Report
After power on, the device will immediately send a version packet report and an attributes report.
The device sends data according to the default configuration before any other configuring.
Default setting:
Report MaxTime
:
Max Interval ----3600s
Report MinTime
:
Min Interval ----3600s (Default: Every Min Interval will detect the state of the dry contact one time)
BatteryVoltageChange ---- 0x01(0.1V)
Triggering the tilt detection:
The device adopts 45° tilt detection around the entire circumference. The initial state of the device is vertical placement.
When the tilt angle (any direction) changes more than 45° (45°~180°), an tipping alarm will be issued immediately.
Device Tilt: 1, Device Recovery: 0