Example of data configuration:
FPort
:
0x07
Bytes
1
1
Var(Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
(1) Configure device parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v
Downlink: 0151003C003C0100000000
Description
Device
Cmd
ID
Devi
ceTy
pe
NetvoxPayLoadData
Config
ReportReq
R313FC
0x01
0x51
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed 0x00)
SetR313F
TypeReq
0x03
R313FType (1Byte)
0x01_R313FA,
0x02_R313FB,
0x03_R313FC
Reserved
(8Bytes,Fixed 0x00)
SetR313F
TypeRsp
0x83
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
GetR313F
TypeReq
0x04
Reserved
(9Bytes,Fixed 0x00)
GetR313F
TypeRsp
0x84
R313FType (1Byte)
0x01_R313FA,
0x02_R313FB,
0x03_R313FC
Reserved
(8Bytes,Fixed 0x00)
SetActive
ThresholdReq
0x05
Threshold
(2Bytes)
Deactivetime
(1Byte,Unit:1s)
Reserved
(6Bytes,Fixed 0x00)
SetActive
ThresholdRsp
0x85
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
GetActive
ThresholdReq
0x06
Reserved
(9Bytes,Fixed 0x00)
GetActive
ThresholdRsp
0x86
Threshold
(2Bytes)
Deactivetime
(1Byte,Unit:1s)
Reserved
(6Bytes,Fixed 0x00)