5
5. Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
The device will immediately send a version packet report and the attribute report data
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 60 min = 3600s
MinTime: Min Interval = 60 min = 3600s
Battery
Voltage
Change
=
0x01 (0.1V)
Threshold = 0x0003 (Threshold range: 0x0003-0x00FF; 0x0003 is the most sensitive.)
Deactivetime = 0x05 (Deactive time range: 0x01-0xFF)
Threshold:
Threshold = Critical value ÷ 9.8 ÷ 0.0625
*The gravitational acceleration at standard atmospheric pressure is 9.8 m/s
2
*The scale factor of the threshold is 62.5 mg
R313FC vibration alarm:
The device detects sudden movement or vibration, and the quiescent state changes. The device waits for a certain period of
time (DeactiveTime) to enter the quiescent state and calculate the duration, sends a report of duration of vibrations, and
restarts the calculation for the next detection. If the vibration continues to occur within (DeactiveTime), the duration will be
continuously calculated till it enters the quiescent state.
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be the minimum time.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver